2012
DOI: 10.1016/j.jhazmat.2012.10.026
|View full text |Cite
|
Sign up to set email alerts
|

Voltammetric analysis with the use of a novel electro-polymerised graphene-nafion film modified glassy carbon electrode: Simultaneous analysis of noxious nitroaniline isomers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 43 publications
(14 citation statements)
references
References 34 publications
0
14
0
Order By: Relevance
“…Lin, Ni, and Kokot made a simultaneous determination of the noxious nitroaniline isomers, by cyclic voltammetry (CV) and DPV, with the electro-polymerization of 7-[(2,4-dihydroxy-5-carboxybenzene)azo]-8-hydroxyquinoline-5-sulfonic acid (DHCBAQS) at a graphene-nafion-modified GCE, denoted at this work as, DHCBAQS/graphenenafion/GCE. The obtained LD was about 0.14 lmol dm -3 for all the compounds [15].…”
Section: Introductionmentioning
confidence: 85%
See 2 more Smart Citations
“…Lin, Ni, and Kokot made a simultaneous determination of the noxious nitroaniline isomers, by cyclic voltammetry (CV) and DPV, with the electro-polymerization of 7-[(2,4-dihydroxy-5-carboxybenzene)azo]-8-hydroxyquinoline-5-sulfonic acid (DHCBAQS) at a graphene-nafion-modified GCE, denoted at this work as, DHCBAQS/graphenenafion/GCE. The obtained LD was about 0.14 lmol dm -3 for all the compounds [15].…”
Section: Introductionmentioning
confidence: 85%
“…Boric acid, acetic acid, phosphoric acid and sodium hydroxide (all p.a. purity, BMIMPF6-SWNT/GCE DPV 0.01-7 8.0 9 10 -9 0.997 [9] SWNT/GCE DPV 0.5-10 2.0 9 10 -7 0.997 [9] CSP/CFE Not available [16] DHCBAQS/graphene-nafion/GCE DPV 0.36-4.31 1.4 9 10 -7 0.999 [15] GCE DPV 2-100 2.0 9 10 -7 0.9906 This work GCE DPV Not available [20] DPV differential pulse voltammetry, AgNPs/POSS/rGO/GCE Glassy carbon electrode modified with nanocomposite of hydrophobic polyhedral oligomeric silsesquioxane and graphene oxide, DTD/AgNP/ CPE 6,7,9,10,17,18,19,20,21, All measurements were carried out using DPV with the following parameters: scan rate 10 mV s -1 , modulation amplitude 50 mV, and pulse duration 50 ms. Based on our previous experience, these parameters give the optimal results. The pH measurements were carried out by the pH meter Jenway 4330 (Jenway, Chelmsford, UK) with a combined glass electrode from the same manufacture.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…(26) EIS was extensively used for studying the interfacial properties of the electrode. (27) The semicircular pattern diameter of the EIS spectrum in the high-frequency region is proportional to the electron transfer resistance (R et ). (28) Accordingly, the estimated R et value of GCE is 45.5 Ω.…”
Section: Electrochemical Behavior Of H-ergomentioning
confidence: 99%
“…Nafion acted as a dispersant for dispersing poly(MImEO8BS)-Ni nanocomposites and can form a uniform film to immobilize the poly(MImEO8BS)-Ni nanocomposites on the glassy carbon electrode (GCE)surface and also as an interferent barrier [66][67][68].…”
Section: Introductionmentioning
confidence: 99%