2007
DOI: 10.1097/01.hp.0000232188.69779.69
|View full text |Cite
|
Sign up to set email alerts
|

Wavelength Dependence of Ocular Damage Thresholds in the Near-Ir to Far-Ir Transition Region: Proposed Revisions to Mpes

Abstract: Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing this collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to Department of Defense, Washington Headquarters Services, Directorate for Info… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
47
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 63 publications
(48 citation statements)
references
References 10 publications
1
47
0
Order By: Relevance
“…Experimental safety studies in the 1300 nm regime report retinal damage thresholds for single-pulse exposures of 50 ns -650 s in rhesus subjects, while continuous wave, CW, exposures of 0.1-10 s can produce corneal lesions, but never retinal damage (Stuck, Lund et al 1980;Lund, Stuck et al 1981;Zuclich, Gagliano et al 1995;Lund, Edsall et al 1998;Zuclich, Lund et al 2001;Zuclich, Lund et al 2004;Zuclich, Lund et al 2007). …”
Section: Motivationmentioning
confidence: 99%
See 4 more Smart Citations
“…Experimental safety studies in the 1300 nm regime report retinal damage thresholds for single-pulse exposures of 50 ns -650 s in rhesus subjects, while continuous wave, CW, exposures of 0.1-10 s can produce corneal lesions, but never retinal damage (Stuck, Lund et al 1980;Lund, Stuck et al 1981;Zuclich, Gagliano et al 1995;Lund, Edsall et al 1998;Zuclich, Lund et al 2001;Zuclich, Lund et al 2004;Zuclich, Lund et al 2007). …”
Section: Motivationmentioning
confidence: 99%
“…Retinal damage threshold studies have been conducted for wavelengths ranging from the ultraviolet (UV) to the infrared (IR) for continuous wave (CW) down to the ultra-short femtosecond pulses (Lund, Stuck et al 1981;Yumita, Shirato et al 1986;Brancato, Praresi et al 1989;Cain, Toth et al 1998;Lund, Edsall et al 1998;ICNIRP 2000;Zuclich, Lund et al 2004;Zuclich, Lund et al 2007). Numerous studies have augmented retinal damage to observe discrete mechanisms contributing to the damage process, such as beam shape, retinal spot size and exposure duration (Zuclich, Lund et al 1999;Cain, Noojin et al 2003).…”
Section: Review Of Corneal and Retinal Threshold Studiesmentioning
confidence: 99%
See 3 more Smart Citations