2013 IEEE International Symposium on Medical Measurements and Applications (MeMeA) 2013
DOI: 10.1109/memea.2013.6549761
|View full text |Cite
|
Sign up to set email alerts
|

Wearable biopotential measurement using the TI ADS1198 analog front-end and textile electrodes

Abstract: The development of mobile systems for monitoring bioelectric signals outside a hospital environment involves many challenges that do not arise when it is in a controlled environment, like a hospital. The dimensions of these systems are an important factor to consider in order to facilitate their use without interfering with the daily activities of individuals.The purpose of this work is the implementation of a singlesupply battery-powered, low power ECG/EMG signal monitoring system based on the ADS1198 Analog … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0
1

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
4
1

Relationship

1
9

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 12 publications
0
7
0
1
Order By: Relevance
“…, making sodium ions (Na + ) continuously transfer to the intracellular, and the membrane potential outside is lower than the membrane potential inside, forming a negative potential outside but positive inside [6]. Biological signals have some characteristics as followed.…”
Section: Generation Principles and Characteristics Of Biological Signalsmentioning
confidence: 99%
“…, making sodium ions (Na + ) continuously transfer to the intracellular, and the membrane potential outside is lower than the membrane potential inside, forming a negative potential outside but positive inside [6]. Biological signals have some characteristics as followed.…”
Section: Generation Principles and Characteristics Of Biological Signalsmentioning
confidence: 99%
“…Human body is composed of cell membrane which is a kind of semi-permeable membrane. The principle of semipermeable membrane is that only a certain kind of ions can go through it in a certain state [1]. It's known that there are a series of physiological and chemical changes in the body when a man is in motion.…”
Section: Generation Principles Of Biological Signalsmentioning
confidence: 99%
“…This integrated circuit (IC) embeds several features commonly used in ECG applications, thus reducing the requirements of external circuitry, allowing to save board area and to reduce power consumption. Chips of this family have been already adopted in previous works in the literature, such as the ADS1198 in [7], where a preprocessing stage is designed for the needs of the test with textile electrodes, and the acquisition is controlled directly by a LabView interface, and in [8] where an ADS1298-based preprocessing system for ECG acquisition is presented.…”
Section: A Input Stage Designmentioning
confidence: 99%