2021
DOI: 10.1039/c9fd00111e
|View full text |Cite
|
Sign up to set email alerts
|

White graphene quantum dots as electrochemical sensing platform for ferritin

Abstract: The use of hexagonal boron nitride quantum dots (hBN QDs) as an electrochemical sensor for ferritin is reported for the first time in this manuscript. These QDs were synthesized using...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
9
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 28 publications
(10 citation statements)
references
References 26 publications
1
9
0
Order By: Relevance
“…Therefore, the utilization of QDs in a biosensing platform can increase the linear operating range of a sensor. A similar advantage was observed in the work reported by Garg et al [ 81 ]. Tanak et al [ 98 ] used impedimetric sensor-based zinc oxide-modified gold-interdigitated electrodes for PCT detection for sepsis diagnosis.…”
Section: Infection-mediated Clinical Biomarkers and Their Electrical Biosensorssupporting
confidence: 89%
See 1 more Smart Citation
“…Therefore, the utilization of QDs in a biosensing platform can increase the linear operating range of a sensor. A similar advantage was observed in the work reported by Garg et al [ 81 ]. Tanak et al [ 98 ] used impedimetric sensor-based zinc oxide-modified gold-interdigitated electrodes for PCT detection for sepsis diagnosis.…”
Section: Infection-mediated Clinical Biomarkers and Their Electrical Biosensorssupporting
confidence: 89%
“…The sensor exhibited a linear range of 10–1500 ng/mL and an LOD of 6.048 and 3.800 ng/mL for cyclic voltammetry and direct pulse voltammetry, respectively. Garg et al [ 81 ] used transition metal chalcogenides (TMDs), which were hexagonal boron nitride (HBN) QDs, for sensing serum ferritin. The use of HBN QDs, also known as white graphene, improved the linear range and LOD for serum ferritin detection.…”
Section: Infection-mediated Clinical Biomarkers and Their Electrical Biosensorsmentioning
confidence: 99%
“…In an effort, to further improve both the linear range and LOD, white graphene QDs (hexagonal boron nitride QDs), were deployed for sensor functionalization and system was able to provide much wider linear range than our previous work. The linear range in this case was 10–2000 ng/mL and LOD value was calculated to be 1.306 ng/mL ( Singh et al, 2020 ). More recently, a graphene modified paper based electrochemical sensor for ferritin was also reported ( Boonkaew et al, 2020 ), in which the antibodies were attached to the electrode surface using the EDC/NHS chemistry.…”
Section: Inflammatory Biomarkers and Their Detection Platformsmentioning
confidence: 91%
“…Electrochemical impedance spectroscopy is used in a platform where hBN QDs are a functionalized detection platform for screen-printed electrodes. The developed immune sensor has a linear range from 10 to 2000 ng/ml -1 ferritin concentration with a detection limit of 1.306 ng/ml -1 ( 56 ).…”
Section: Nanoparticle-based Detection Strategies Of Covid-19mentioning
confidence: 99%