2019
DOI: 10.1097/md.0000000000014207
|View full text |Cite
|
Sign up to set email alerts
|

Wiener filter improves diagnostic accuracy of CAD SPECT images—comparison to angiography and CT angiography

Abstract: Many discrepancy in selection of proper filter and its parameters for individual cases exists. The authors investigate the impact of the most common filters on patient NM images with coronary artery disease (CAD), and compare the results with the computerized tomography (CT)-Angio and angiography for accuracy.The investigation initiated by performing various single photon emission computerized tomography (SPECT)/CT scan of the national electrical manufacturers association chest phantoms having hot and cold ins… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…Masoomi et al (2019) [11] Data: images of chest phantoms as well as 92 patients (41-77 years) with CAD filters: Butterworth, Metz, Hamming, and Wiener Radioisotope: 99m T c Reconstruction method: filtered back projection (FBP)…”
Section: Materials and Methods Results Conclusionmentioning
confidence: 99%
“…Masoomi et al (2019) [11] Data: images of chest phantoms as well as 92 patients (41-77 years) with CAD filters: Butterworth, Metz, Hamming, and Wiener Radioisotope: 99m T c Reconstruction method: filtered back projection (FBP)…”
Section: Materials and Methods Results Conclusionmentioning
confidence: 99%
“…On the basis of the ECG, involvement suspicion could be raised of a lesion of the right coronary one, potentially eligible for PCI. Indeed, the coronary angiography evidenced, in addition to the left coronary lesion, a severe proximal stenosis of the right coronary artery, not detected by angio-CT. We hypothesize that this might be due to motion artifacts related to high heart rate, a known limitation of coronary angio-CT in children [ 29 ]. The critical involvement at the origin of the two main coronary arteries is a life-threatening condition and usually requires surgical treatment in adult patients [ 30 ].…”
Section: Discussionmentioning
confidence: 99%
“…Due to noise in the PET images all calculations were conducted after applying the Wiener filter (PSF = 5, noise to signal ratio = 0.11) [25].…”
Section: Plos Onementioning
confidence: 99%