Wind Forces on Photovoltaic Panels Mounted on Gable Roof With Japanese Roof Tiles
Tsuyoshi MURAKAMI,
Takashi MARUYAMA
Abstract:The wind tunnel test examines the wind force using gable roof house models with Japanese roof tiles, which is not included in JIS C8955 as the design standard for photovoltaic panels. The test results show the maximum peak wind force for the panels on Japanese roof tiles in all wind directions is within that for the panels on flat surface roof in JIS C8955. On the other hand, the peak wind force on a panel on Japanese roof tiles is greater than that on the panel on flat surface roof in specific wind directions. Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.