2016
DOI: 10.1063/1.4937537
|View full text |Cite
|
Sign up to set email alerts
|

X-ray grating interferometry for 9.25 keV design energy at a liquid-metal-jet source

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
5
0
1

Year Published

2017
2017
2021
2021

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 16 publications
0
5
0
1
Order By: Relevance
“…In the last years, the single-grating approach has seen increasing interest and a number of setups have been reported in the literature using either a single phase or absorption grating to create an interference pattern combined with a phase-stepping scan Balles et al, 2016;Schulz et al, 2017b;Balles et al, 2018;Yang et al, 2019]. Experimental implementations of single-shot single-grating measurements for high-speed imaging have been proposed using 1D and 2D…”
Section: Grating Interferometry Without Absorption Grating G2mentioning
confidence: 99%
See 1 more Smart Citation
“…In the last years, the single-grating approach has seen increasing interest and a number of setups have been reported in the literature using either a single phase or absorption grating to create an interference pattern combined with a phase-stepping scan Balles et al, 2016;Schulz et al, 2017b;Balles et al, 2018;Yang et al, 2019]. Experimental implementations of single-shot single-grating measurements for high-speed imaging have been proposed using 1D and 2D…”
Section: Grating Interferometry Without Absorption Grating G2mentioning
confidence: 99%
“…All of the above results were obtained with X-ray beams of sufficient spatial coherence to observe the self-image of the G1 phase grating without G0. This is the case for synchrotron sources, but also achievable at high-end laboratory sources such as the liquid-metal-jet source (see Chapter 2, Section 2.6.1), for which a single-grating setup has been demonstrated as well [Balles et al, 2016[Balles et al, , 2018. Moreover, analogous to the classic Talbot-Lau interferometer with three gratings, a G2-less setup can also be realised at conventional tube source with low spatial coherence by adding a source grating G0.…”
Section: Grating Interferometry Without Absorption Grating G2mentioning
confidence: 99%
“…The conventional implementations of XGI at synchrotrons use a setup with a beam-splitter phase grating and an absorption grating that converts the high-frequency interference pattern into intensity modulations in the detector pixels while one of the gratings is stepped perpendicular to the grating lines, known as phase-stepping scan. A simpler and more robust setup can be achieved with the use of only a single phase grating, which has been reported for single-shot measurements with 2D and 1D gratings [ 29 31 ]. Recently, a setup using the phase-stepping approach with a single line grating has been proposed allowing more dose- and time-efficient imaging with a simple arrangement albeit a decreased spatial resolution [ 32 ].…”
Section: Introductionmentioning
confidence: 99%
“…径的探索中, Endrizzi等 [4] 、Fu等 [5] 、Wei等 [6] 以 及Ge等 [7] [8] 、 Marathe [9] 以 及 Wen [10] 、Bennett [11] 等验证了第二种途径的可行性, 此后基于免分析光栅X射线相位衬度成像系统的 一次曝光成像理论的发展受到了广泛的关注. 但是 目前基于该成像理论的样品信息提取算法还不完 善.…”
unclassified