2015
DOI: 10.1002/mrm.25545
|View full text |Cite
|
Sign up to set email alerts
|

Zero TEMR bone imaging in the head

Abstract: PD-weighted ZT imaging provides robust and efficient depiction of bone structures in the head, with an excellent contrast between air, soft-tissue, and bone. Besides structural bone imaging, the presented method is expected to be of relevance for attenuation correction in positron emission tomography (PET)/MR and MR-based radiation therapy planning.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
230
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 206 publications
(233 citation statements)
references
References 35 publications
3
230
0
Order By: Relevance
“…In fact, this approach has been proposed to correct the EPI distortion of a moving phantom (40). For human subjects, anatomical scans revealing the air cavities against bone and soft tissue may support this predictive model, e.g., scans based on ultrashort or zero echo-time designs (41–43). The influence of the neck and torso can potentially be modeled using simplified geometry with appropriate susceptibility values (41).…”
Section: Discussionmentioning
confidence: 99%
“…In fact, this approach has been proposed to correct the EPI distortion of a moving phantom (40). For human subjects, anatomical scans revealing the air cavities against bone and soft tissue may support this predictive model, e.g., scans based on ultrashort or zero echo-time designs (41–43). The influence of the neck and torso can potentially be modeled using simplified geometry with appropriate susceptibility values (41).…”
Section: Discussionmentioning
confidence: 99%
“…Zero echo time (ZTE) and ultrashort echo time (UTE) pulse sequences use specialized acquisition and reconstruction techniques to enable detection of ultrashort-T2 components in vivo. These sequences allow for direct visualization of tendons ( T210.16667emms) (1–7), cortical bone ( T20.40.16667emms) (816), and lung parenchyma ( T20.5-30.16667emms) (1722), as well as components in myelin ( T20.1-0.40.16667emms (2325)) and ligaments (26) (up to 80% fraction of T210.16667emms (27)).…”
Section: Introductionmentioning
confidence: 99%
“…The majority of these approaches rely on UTE or ZTE MR techniques that have very short or zero echo times 23,24,27,30,47,48 . These approaches potentially will provide lung, bone and soft tissue maps allowing for accurate patient specific attenuation correction.…”
Section: Direct Imaging Methodsmentioning
confidence: 99%
“…Wiesinger et al proposed a ZTE method to image bone 47 . Imaging parameters of the ZTE protocol were chosen to generate proton density weighted images.…”
Section: Direct Imaging Methodsmentioning
confidence: 99%