Zika Virus Non-Structural Protein 1 Antigen-Capture Immunoassay

Abstract: Infection with Zika virus (ZIKV), a member of the Flavivirus genus of the Flaviviridae family, typically results in mild self-limited illness, but severe neurological disease occurs in a limited subset of patients. In contrast, serious outcomes commonly occur in pregnancy that affect the developing fetus, including microcephaly and other major birth defects. The genetic similarity of ZIKV to other widespread flaviviruses, such as dengue virus (DENV), presents a challenge to the development of specific ZIKV dia… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
8
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(10 citation statements)
references
References 64 publications
2
8
0
Order By: Relevance
“…The assays based on rabbit anti-ZIKV NS1 pAb and mAb 2F2 showed similar detection limits to DENV-NS1 capture ELISAs, such as SD Bioline’s detection limit of between 16 and 63 ng/mL NS1 [ 48 ]. Moreover, our results are in line with an antigen-capture ELISA configured with the affinity-purified anti-ZIKV NS1 pAb, for which the reported limit of detection was between 1.95 and 7.8 ng/mL [ 42 ].…”
Section: Discussionsupporting
confidence: 80%
See 3 more Smart Citations
“…The assays based on rabbit anti-ZIKV NS1 pAb and mAb 2F2 showed similar detection limits to DENV-NS1 capture ELISAs, such as SD Bioline’s detection limit of between 16 and 63 ng/mL NS1 [ 48 ]. Moreover, our results are in line with an antigen-capture ELISA configured with the affinity-purified anti-ZIKV NS1 pAb, for which the reported limit of detection was between 1.95 and 7.8 ng/mL [ 42 ].…”
Section: Discussionsupporting
confidence: 80%
“…The mentioned similarities guided us to test a small ZIKV sera panel obtained from infected patients and validated by qRT-PCR. The results showed an accuracy of 77.2%, which was superior to the one previously obtained by Beddingfield et al (2021) [ 42 ], for which the detection limit was similar to the one obtained by us (55.5% vs. 55.7%). Additionally, other studies have been published with similar approaches based on capturing ZIKV-NS1 [ 45 ].…”
Section: Discussionsupporting
confidence: 54%
See 2 more Smart Citations
“…The data in Table S4 demonstrate that the lateral flow tests detect Dengue NS1 proteins in the range of 30-100 ng/ml, while the concentration of circulating Dengue NS1 protein has been reported to reach 15-50 micrograms/ml [5]. The limit of detection for Zika virus NS1 protein is approximately 220 ng/ml (Table S4), while circulating Zika virus NS1 levels has been reported to reach about 2 micrograms/ml [16].…”
Section: Detecting and Distinguishing Dengue Disease From Zika Virus ...mentioning
confidence: 95%