We demonstrate plasma discharges with extremely high temperature of bulk electrons at the large axially symmetric magnetic mirror device GDT (Budker Institute, Novosibirsk). According to Thomson scattering measurements, the on-axis electron temperature averaged over several sequential shots is 660 ± 50 eV with peak values exceeding 900 eV in few shots. This corresponds to at least threefold increase as compared to previous experiments both at the GDT and at other comparable machines, thus demonstrating the maximum quasi-stationary (∼ 1 ms) electron temperature achieved in open traps. The breakthrough is made possible with application of sophisticated electron cyclotron resonance heating in addition to standard heating by neutral beams. The reported increase of the electron temperature along with previous experiments, which demonstrated highdensity plasma confinement with β ≈ 60%, provide a firm basis for extrapolating to fusion relevant applications of open magnetic systems.
This paper summarizes the results of experiments on electron cyclotron resonance heating (ECRH) of plasma obtained at the axially symmetric magnetic mirror device gas dynamic trap (GDT) (Budker Institute, Novosibirsk). The main achievement is the demonstration of plasma discharges with extremely high temperatures of bulk electrons. According to the Thomson scattering measurements, the on-axis electron temperature averaged over several sequential shots is 660 ± 50 eV with peak values exceeding 900 eV in a few shots. This corresponds to an at least threefold increase as compared to previous experiments both at the GDT and at other comparable machines, thus demonstrating the maximum quasi-stationary (∼0.6 ms) electron temperature achieved in open traps. The breakthrough is made possible with the successful implementation of a sophisticated ECRH scheme in addition to standard heating by neutral beams (NBs). Another important result is the demonstration of the significantly increased lifetime of NB-driven fast particles with the application of ECRH, leading to a 30% higher plasma energy content at the end of the discharge. All available data including the previously demonstrated possibility of plasma confinement with β as high as 60%, allows us to consider fusion applications of axially symmetric magnetic mirror machines on a realistic basis.
Articles you may be interested inCO2 laser-based dispersion interferometer utilizing orientation-patterned gallium arsenide for plasma density measurements Rev. Sci. Instrum. 84, 093502 (2013); 10.1063/1.4819028 First results from the modular multi-channel dispersion interferometer at the TEXTOR tokamak Rev. Sci. Instrum. 82, 063509 (2011); 10.1063/1.3600896Edge transport and turbulence reduction with lithium coated plasma facing components in the National Spherical Torus Experiment a)A dispersion interferometer based on a continuous-wave CO 2 laser source ͑ = 9.57 m͒ with double plasma passage for measurements of the line-integrated electron density in the TEXTOR tokamak and the GDT linear system has been developed and tested in experiments. A sensitivity of ͗n e l͘ min =2ϫ 10 17 m −2 and a temporal resolution of 1 ms have been achieved. The interferometer does not need any rigid frame for vibration insulation. Its basic components are installed compactly on an optical bench placed on a stable support outside of the torus. The possibility for the development of a multichannel dispersion interferometer for the next generation of fusion devices ͑e.g., W7-X, ITER͒ is discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.