Background-Omega-3 fatty acids (FAs) appear to reduce the risk of sudden death from myocardial infarction. This reduction is believed to occur via the incorporation of eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) into the myocardium itself, altering the dynamics of sodium and calcium channel function. The extent of incorporation has not been determined in humans. Methods and Results-We first determined the correlation between red blood cell (RBC) and cardiac omega-3 FA levels in 20 heart transplant recipients. We then examined the effects of 6 months of omega-3 FA supplementation (1 g responses among tissues were not significantly different). Conclusions-Although any of the tissues examined could serve as a surrogate for cardiac omega-3 FA content, RBC EPAϩDHA was highly correlated with cardiac EPAϩDHA; the RBC omega-3 response to supplementation was similar to that of the heart; RBCs are easily collected and analyzed; and they have a less variable FA composition than plasma. Therefore, RBC EPAϩDHA (also called the Omega-3 Index) may be the preferred surrogate for cardiac omega-3 FA status.
Background— Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. Methods and Results— We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P <0.001) and an increase in valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P <0.001). No procedural complications were reported. Conclusions— BVF can be performed safely in small surgical valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.