Diabetes is associated with increased ECV. Extracellular volume fraction detects amelioration of ECM expansion associated with RAAS blockade, and is associated with mortality and/or incident hospitalization for heart failure in diabetic individuals. Extracellular matrix expansion may be an important intermediate phenotype in diabetic individuals that is detectable and treatable.
Among myriad changes occurring during the apparent evolution of HFpEF where elevated BNP is prevalent, MF was similarly prevalent in those with or at risk for HFpEF. Conceivably, MF might precede clinical HFpEF diagnosis. Regardless, MF was associated with disease severity (ie, BNP) and outcomes. Whether cells and secretomes mediating MF represent therapeutic targets in HFpEF warrants further evaluation.
Background
Due to anatomic and physiologic concerns, prior generations of the left ventricular assist devices (LVAD) have frequently been denied to patients with small body size. However, outcomes in patients with small body surface area (BSA) following HeartMate 3 (HM3) LVAD implantation remain relatively unknown.
Methods
A cohort of 220 patients implanted at a single center was divided into two groups: BSA ≤1.8 m2 (small BSA, n = 37) and BSA >1.8 m2 (large BSA, n = 183). We investigated baseline characteristics and clinical outcomes including survival and incidence of adverse events.
Results
Small BSA patients were older (60 vs. 57 years), more likely female (60% vs. 20%), had a lower body mass index (24 vs. 32 kg/m2), lower incidence of diabetes (32% vs. 51%), history of stroke (5% vs. 19%), and left ventricular thrombus (0% vs. 11%). They had smaller left ventricular end diastolic diameter (64.8 vs. 69.3 mm). Pump speed and pump flows at discharge were lower in the small BSA group. Survival at 1 year and 2 years was 86% versus 87% and 86% versus 79% for small versus large BSA groups (p = 0.408), respectively. The rates of adverse events were similar between groups and there were no cases of confirmed pump thrombosis. The incidence of readmissions for low flow alarms was higher in the small BSA group (0.55 vs. 0.24 EPPY).
Conclusions
These findings demonstrate comparable outcomes in patients with small body size and suggest that this parameter should not be an exclusion criterion on patients who are otherwise candidates for HM3 LVAD implantation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.