Presented here was an outline of fatal myocardial sarcoidosis in Japan based on 42 autopsy cases. The incidence, clinical features, pathological findings (particularly the distribution of sarcoid lesions in various organs, and gross as well as histological patterns have been reviewed. The ratio of fatal myocardial sarcoidosis to the total number of sarcoidosis deaths is higher than that of other countries and it appears characteristic of Japanese sarcoidosis that the disease occurs here predominantly after the fourth decade in females. Only 12% of myocardial sarcoidosis cases are diagnosed exactly. Conduction disturbances and dysrhythmias due to myocardial damage are its most common manifestations. The modes of presentation or cardiac death are sudden death, 16 cases (41%); congestive heart failure, 9 cases (23.1%); Adams-Stokes syndrome, except sudden death, 7 cases (17.9%); death due to dysrhythmia, 6 cases (15.4%); and 2 pacemaker deaths among the application of pacemakers, 7 cases. As for the ECG findings, A-V block and bundle-branch block was observed in most cases and ectopic beats were also frequently observed. The difficulty in exact diagnosis of myocardial sarcoidosis appears to be due to the frequency of lack of manifestation of systemic sarcoidosis as well as insidious cardiac involvement. The gross findings on myocardial lesions showed 3 patterns and each of the localized patterns corresponded to the histological extension. The conglomerate-band-like pattern corresponded to expansive invasion, the dendrite pattern to interstitial extension. The histological findings on the myocardial lesions were classified into four types: 1) exudative type, 2) granuloma type, 3) combined type of granuloma and fibrosis, 4) fibrotic type. Two extreme cases showed the exudative and fibrotic type, respectively, and were discussed.
We developed a new coating material (Toyobo-National Cardiovascular Center coating) for medical devices that delivers high antithrombogenicity and long-term durability. We applied this coating to an extracorporeal membrane oxygenation (ECMO) system, including the circuit tube, cannulae, a seal-less centrifugal pump, and a diffusion membrane oxygenator, to realize prolonged cardiopulmonary support with trivial anticoagulant infusion. The oxygenator consisted of a hollow-fiber membrane made of polymethylpentene, which allows the transfer of gas by diffusion through the membrane. The centrifugal pump was free of seals and had a pivot bearing. We performed a venoarterial bypass in a goat using this ECMO system, and the system was driven for 151 days with trivial anticoagulant infusion. Plasma leakage from the oxygenator did not occur and sufficient gas-exchange performance was well maintained. In the oxygenator, thrombus formation was present around the top and the distributor of the inlet portion and was very slight in the outlet portion. In the centrifugal blood pump, there was some wear in the female pivot region and quite small amounts of thrombus formation on the edge of the shroud; the pivot wear seemed to be the cause of the hemolysis observed after 20 weeks of perfusion and which resulted in the termination of the perfusion. However, no significant amounts of thrombus were observed in other parts of the system. This ECMO system showed potential for long-term cardiopulmonary support with minimal use of systemic anticoagulants.
We developed an extracorporeal membrane oxygenation (ECMO) system with high antithrombogenicity and durability characteristics for prolonged continuous cardiopulmonary support. The oxygenator consists of a special hollow-fiber-type polyolefin gas-exchange membrane, which has an ultrathin dense layer in contact with the blood, in order to prevent plasma leakage during protracted use (Platinum Cube NCVC). The centrifugal pump (RotaFlow) is free of seals. The entire blood-contacting surface of the system is coated with a newly developed heparin material (Toyobo-NCVC coating). We performed a venoarterial bypass in a goat, and the ECMO system was driven for 34 days without systemic anticoagulants. Plasma leakage from the oxygenator did not occur, and sufficient gas exchange performance was maintained. Thrombus formation was hardly observed in the ECMO system except in the casing margins of the oxygenator. This ECMO system showed potential for long-term cardiopulmonary support with minimal or no use of systemic anticoagulants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.