Background: Direct laryngoscopy (DL) has long been the most common approach for emergency endotracheal intubation, although the use of video laryngoscopy (VL) is becoming more widespread. Current observational data suggest that VL has higher first-pass success, although randomized trials are lacking.
Objectives: Inferior vena cava collapsibility (cIVC) measured by point-of-care ultrasound (POCUS) has been proposed as a noninvasive means of assessing fluid responsiveness. We aimed to prospectively evaluate the performance of a 25% cIVC cutoff value to detect fluid responsiveness among spontaneously breathing intensive care unit (ICU) patients when assessed with POCUS by novice versus expert physician sonologists. Methods: Prospective observational study of spontaneously breathing ICU patients. Fluid responsiveness was defined as a >10% increase in cardiac index following a 500 mL fluid bolus, measured by bioreactance. Novice sonologist measured cIVC with POCUS. Their measurements were later compared to an expert physician sonologist who independently reviewed the POCUS images and assessed cIVCs. Results: Of the 85 participants, 44 (52%) were fluid responders. A 25% cIVC cutoff value performed better when assessed by expert sonologists than novice physician sonologists (receiver–operator characteristic curve, ROC = 0.82 [0.74-0.88] vs ROC = 0.69 [0.60-0.77]). Conclusions: A 25% cIVC cutoff value measured by POCUS detects fluid responsiveness. However, the experience of the physician sonologist effects test performance and should be considered when interpreting and clinically using cIVC to direct intravenous fluid resuscitation.
Background Focused cardiac ultrasound (FOCUS) is insensitive for pulmonary embolism (PE). Theoretically, when a clot is large enough to cause vital sign abnormalities, it is more likely to show signs of right ventricular dysfunction on FOCUS, although this has not been well quantified. A rapid bedside test that could quickly and reliably exclude PE in patients with abnormal vital signs could be of high utility in emergency department (ED) patients. We hypothesized that in patients with tachycardia or hypotension, the sensitivity of FOCUS for PE would increase substantially. Methods We performed a prospective observational multicenter cohort study involving a convenience sample of patients from six urban academic EDs. Patients suspected to have PE with tachycardia (heart rate [HR] ≥ 100 beats/min) or hypotension (systolic blood pressure [sBP] < 90 mm Hg) underwent FOCUS before computed tomography angiography (CTA). FOCUS included assessment for right ventricular dilation, McConnell's sign, septal flattening, tricuspid regurgitation, and tricuspid annular plane systolic excursion. If any of these were abnormal, FOCUS was considered positive, while if all were normal, FOCUS was considered negative. We a priori planned a subgroup analysis of all patients with a HR ≥ 110 beats/min (regardless of their sBP). We then determined the diagnostic test characteristics of FOCUS for PE in the entire patient population and in the predefined subgroup, based on CTA as the criterion standard. Inter‐rater reliability of FOCUS was determined by blinded review of images by an emergency physician with fellowship training in ultrasound. Results A total of 143 subjects were assessed for enrollment and 136 were enrolled; four were excluded because they were non–English‐speaking and three because of inability to obtain any FOCUS windows. The mean (±SD) age of enrolled subjects was 56 (±7) years, mean (±SD) HR was 114 (±12) beats/min, and 37 (27.2%) subjects were diagnosed with PE on CTA. In all subjects, FOCUS was 92% (95% confidence interval [CI] = 78% to 98%) sensitive and 64% specific (95% CI = 53% to 73%) for PE. In the subgroup of 98 subjects with a HR ≥ 110 beats/min, FOCUS was 100% sensitive (95% CI = 88% to 100%) and 63% specific (95% CI = 51% to 74%) for PE. There was substantial interobserver agreement for FOCUS (κ = 1.0, 95% CI = 0.31 to 1.0). Conclusions A negative FOCUS examination may significantly lower the likelihood of the diagnosis of PE in most patients who are suspected of PE and have abnormal vital signs. This was especially true in those patients with a HR ≥ 110 beats/min. Our results suggest that FOCUS can be an important tool in the initial evaluation of ED patients with suspected PE and abnormal vital signs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.