The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer testing, and imaging with either pulmonary ventilation-perfusion (V/Q) scintigraphy or pulmonary multidetector CT (MDCT) angiography. Both V/Q SPECT and MDCT angiography seem to have high diagnostic accuracy. However, only limited data directly comparing these 2 modalities are available. Hybrid g-camera/MDCT systems have been introduced and allow simultaneous 3-dimensional lung V/Q SPECT and MDCT angiography, suitable for diagnosing PE. The aim of our study was to compare, in a prospective design, the diagnostic ability of V/Q SPECT, V/Q SPECT combined with low-dose CT, and pulmonary MDCT angiography obtained simultaneously using a combined SPECT/MDCT scanner in patients suspected of having PE. Methods: Consecutive patients from June 2006 to February 2008 suspected of having acute PE were referred to the Department of Nuclear Medicine at Rigshospitalet or Frederiksberg Hospital, Denmark, for V/Q SPECT as a first-line imaging procedure. The number of eligible patients was 196. Patients with positive D-dimer results (.0.5 mmol/mL) or a clinical assessment with a Wells score greater than 2 were included and underwent V/Q SPECT, lowdose CT, and pulmonary MDCT angiography in a single session. Patient follow-up was 6 mo. Results: A total of 81 simultaneous studies were available for analysis, of which 38% were from patients with PE. V/Q SPECT had a sensitivity of 97% and a specificity of 88%. When low-dose CT was added, the sensitivity was still 97% and the specificity increased to 100%. Perfusion SPECT with low-dose CT had a sensitivity of 93% and a specificity of 51%. MDCT angiography alone had a sensitivity of 68% and a specificity of 100%. Conclusion: We conclude that V/Q SPECT in combination with low-dose CT without contrast enhancement has an excellent diagnostic performance and should therefore probably be considered first-line imaging in the workup of PE in most cases.
Background: In animal studies tumor size is used to assess responses to anticancer therapy. Current standard for volumetric measurement of xenografted tumors is by external caliper, a method often affected by error. The aim of the present study was to evaluate if microCT gives more accurate and reproducible measures of tumor size in mice compared with caliper measurements. Furthermore, we evaluated the accuracy of tumor volume determined from 18 Ffluorodeoxyglucose ( 18 F-FDG) PET.
Since the first report of the enhanced permeability and retention (EPR) effect, the research in nanocarrier based antitumor drugs has been intense. The field has been devoted to treatment of cancer by exploiting EPR-based accumulation of nanocarriers in solid tumors, which for many years was considered to be a ubiquitous phenomenon. However, the understanding of differences in the EPR-effect between tumor types, heterogeneities within each patient group, and dependency on tumor development stage in humans is sparse. It is therefore important to enhance our understanding of the EPR-effect in large animals and humans with spontaneously developed cancer. In the present paper, we describe a novel loading method of copper-64 into PEGylated liposomes and use these liposomes to evaluate the EPR-effect in 11 canine cancer patients with spontaneous solid tumors by PET/CT imaging. We thereby provide the first high-resolution analysis of EPR-based tumor accumulation in large animals. We find that the EPR-
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.