Background
Radiofrequency high‐power ablation appears to be a novel concept for atrial fibrillation (AF). The ablation index (AI) value has been associated with durability of pulmonary vein isolation (PVI).
Objectives
This study aimed to report the procedural data and initial results of a combined ablation technique using AI‐guided high‐power (AI‐HP; 50 W) ablation for PVI.
Methods
Symptomatic AF patients were consecutively enrolled and underwent wide‐area contiguous circumferential PVI. Contact‐force catheters were used, ablation power was set to 50 W targeting AI values (550 anterior and 400 posterior). Esophageal temperature was monitored during procedure, all patients underwent postablation esophageal endoscopy.
Results
PVI was achieved in all (n = 50, mean age: 68 ± 9 years, female: 60%) patients, rate of first‐round PVI was 92%. A total of N = 2105 AI‐guided ablation lesions were analyzed. Comparing left anterior wall vs left posterior wall and right anterior wall vs right posterior wall, mean ablation time (s) per lesion was 20.5 ± 8 vs 8.6 ± 3 and 12.2 ± 4 vs 9.3 ± 3; mean contact force (g): 17.1 ± 12 vs 25.4 ± 14 and 33.7 ± 13 vs 21.0 ± 11; mean AI: 547 ± 48 vs 445 ± 55 and 555 ± 56 vs 440 ± 47 (all P < .0001). Procedure and fluoroscopy time (minute) were 55.6 ± 6.6 and 6 ± 1.7, respectively. Only one (2%) patient had a minimal esophageal lesion. During In‐hospital and 1‐month follow‐up no major complications such as death, stroke, tamponade, or atriaesophageal fistula (AE) occurred. Preliminary 6‐month follow‐up showed 48 of 50 (96%) patients were free from clinical AF/atrial tachycardia recurrence.
Conclusion
AI‐HP (50 W) ablation appears to be a feasible, safe, fast, and effective ablation technique for PVI.
The risk for CT in patients undergoing AF ablation at a single high-volume center was decreased with the use of balloon catheters. Extensive radiofrequency current ablation beyond PVI leads to an increased perforation risk.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.