HF10 therapy promises to substantially impact the management of back and leg pain with broad applicability to patients, physicians, and payers.
BACKGROUND:Pain relief with spinal cord stimulation (SCS) has focused historically on paresthesias overlapping chronically painful areas. A higher level evidence supports the use of SCS in treating leg pain than supports back pain, as it is difficult to achieve adequate paresthesia coverage, and then pain relief, in the low back region. In comparison, 10-kHz high-frequency (HF10 therapy) SCS therapy does not rely on intraoperative paresthesia mapping and remains paresthesia-free during therapy.OBJECTIVE:To compare long-term results of HF10 therapy and traditional low-frequency SCS.METHODS:A pragmatic randomized, controlled, pivotal trial with 24-month follow-up was conducted across 11 comprehensive pain treatment centers. Subjects had Visual Analog Scale scores of ≥5.0/10.0 cm for both back and leg pain, and were assigned randomly (1:1) to receive HF10 therapy or low-frequency SCS. The primary end point was a responder rate, defined as ≥50% back pain reduction from baseline at 3 months with a secondary end point at 12 months (previously reported). In this article, 24-month secondary results are presented. Non-inferiority was first assessed, and if demonstrated the results were tested for superiority.RESULTS:In the study, 198 subjects were randomized (101 HF10 therapy, 97 traditional SCS). One hundred seventy-one subjects (90 HF10 therapy, 81 traditional SCS) successfully completed a short-term trial and were implanted. Subjects averaged 54.9 ± 12.9 years old, 13.6 ± 11.3 years since diagnosis, 86.6% had back surgery, 88.3% were taking opioid analgesics. At 3 months, 84.5% of implanted HF10 therapy subjects were responders for back pain and 83.1% for leg pain, and 43.8% of traditional SCS subjects were responders for back pain and 55.5% for leg pain (P < .001 for both back and leg pain comparisons, non-inferiority and superiority). At 24 months, more subjects were responders to HF10 therapy than traditional SCS (back pain: 76.5% vs 49.3%; 27.2% difference, 95% CI, 10.1%-41.8%; P < .001 for non-inferiority and superiority; leg pain: 72.9% vs 49.3%; 23.6% difference, 95% CI, 5.9%-38.6%; P < .001 for non-inferiority and P = .003 for superiority). Also at 24 months, back pain decreased to a greater degree with HF10 therapy (66.9% ± 31.8%) than traditional SCS (41.1% ± 36.8%, P < .001 for non-inferiority and superiority). Leg pain also decreased to a greater degree with HF10 therapy (65.1% ± 36.0%) than traditional SCS (46.0% ± 40.4%, P < .001 for non-inferiority and P = .002 for superiority).CONCLUSION:This study demonstrates long-term superiority of HF10 therapy compared with traditional SCS in treating both back and leg pain. The advantages of HF10 therapy are anticipated to impact the management of chronic pain patients substantially.ABBREVIATIONS:IPG, implantable pulse generatorMCID, minimal clinically important differencePI, permanent implantODI, Oswestry Disability IndexSCS, spinal cord stimulationVAS, Visual Analog Scale
BackgroundThe past two decades have witnessed a surge in the use of lumbar facet blocks and radiofrequency ablation (RFA) to treat low back pain (LBP), yet nearly all aspects of the procedures remain controversial.MethodsAfter approval by the Board of Directors of the American Society of Regional Anesthesia and Pain Medicine, letters were sent to a dozen pain societies, as well as representatives from the US Departments of Veterans Affairs and Defense. A steering committee was convened to select preliminary questions, which were revised by the full committee. Questions were assigned to 4–5 person modules, who worked with the Subcommittee Lead and Committee Chair on preliminary versions, which were sent to the full committee. We used a modified Delphi method, whereby the questions were sent to the committee en bloc and comments were returned in a non-blinded fashion to the Chair, who incorporated the comments and sent out revised versions until consensus was reached.Results17 questions were selected for guideline development, with 100% consensus achieved by committee members on all topics. All societies except for one approved every recommendation, with one society dissenting on two questions (number of blocks and cut-off for a positive block before RFA), but approving the document. Specific questions that were addressed included the value of history and physical examination in selecting patients for blocks, the value of imaging in patient selection, whether conservative treatment should be used before injections, whether imaging is necessary for block performance, the diagnostic and prognostic value of medial branch blocks (MBB) and intra-articular (IA) injections, the effects of sedation and injectate volume on validity, whether facet blocks have therapeutic value, what the ideal cut-off value is for a prognostic block, how many blocks should be performed before RFA, how electrodes should be oriented, the evidence for larger lesions, whether stimulation should be used before RFA, ways to mitigate complications, if different standards should be applied to clinical practice and clinical trials and the evidence for repeating RFA (see table 12 for summary).ConclusionsLumbar medial branch RFA may provide benefit to well-selected individuals, with MBB being more predictive than IA injections. More stringent selection criteria are likely to improve denervation outcomes, but at the expense of more false-negatives. Clinical trials should be tailored based on objectives, and selection criteria for some may be more stringent than what is ideal in clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.