Precis: This study is the first to report micropulse transscleral cyclophotocoagulation (MP-TSCPC) use in only good vision patients. MP-TSCPC significantly reduced intraocular pressure (IOP) and glaucoma medication use without any significant reduction in visual acuity at every postoperative follow-up point. Purpose: To evaluate outcomes of MP-TSCPC in eyes with baseline best-corrected visual acuity (BCVA) of ≥20/60. Methods: A retrospective review of patients who underwent MP-TSCPC at Mayo Clinic and Ross Eye Institute from July 2016 to August 2017 with BCVA of ≥20/60, and a minimum of 3 months follow-up. Results: A total of 61 eyes of 46 patients (68.80±17.12 y) underwent MP-TSCPC with a mean follow-up of 10.2±3.1 months. Mean IOP and mean number of glaucoma medications used were significantly reduced from baseline at every follow-up time point (P<0.0001). At month 12, mean IOP was reduced 40.2% from baseline with 85.4% of the patients having an IOP reduction of ≥20%, and mean glaucoma medication use reduced by 0.82±0.53 with 79.6% of the patients having a reduction of ≥1 medication. There was no significant reduction in BCVA from baseline at any follow-up point (P>0.05), except for 10 eyes with a vision loss of ≥2 lines and 5 out of 10 eyes had cataract progression. The probability of complete success (IOP range, 6 to 21 mm Hg or ≥20% IOP reduction; BCVA loss ≤2 lines, no reoperation for glaucoma) was 74.14%, 83.61%, 84.21%, and 75.0% at months 1, 3, 6, 12, respectively. The probability of qualified success (above criteria for IOP, no reoperation and BCVA loss >2 lines) was 81.03%, 91.80%, 94.74%, and 93.75% at months 1, 3, 6, 12, respectively. Conclusions: MP-TSCPC should be considered earlier in the management of glaucoma and can possibly be offered as an alternative to incisional glaucoma surgeries.
Aim: To study the microvascular density of the macular and optic nerve head in healthy and glaucoma subjects using optical coherence tomography angiography. Methodology: We performed a cross-sectional cohort study on healthy subjects and patients with glaucoma. The AngioVue Enhanced Microvascular Imaging System was used to capture the optic nerve head and macula images during one visit. En face segment images of the macular and optic disc were studied in layers. Microvascular density of the optic nerve head and macula were quantified by the number of pixels measured by a novel in-house developed software. Areas under the receiver operating characteristic curves (AUROC) were used to determine the accuracy of differentiating between glaucoma and healthy subjects. Results: A total of 24 (32 eyes) glaucoma subjects (57.5±9.5-y old) and 29 (58 eyes) age-matched controls (51.17±13.5-y old) were recruited. Optic disc and macula scans were performed showing a greater mean vessel density (VD) in healthy compared with glaucoma subjects. The control group had higher VD than the glaucoma group at the en face segmented layers of the optic disc (optic nerve head: 0.209±0.05 vs. 0.110±0.048, P<0.001; vitreoretinal interface: 0.086±0.045 vs. 0.052±0.034, P=0.001; radial peripapillary capillary: 0.146±0.040 vs. 0.053±0.036, P<0.001; and choroid: 0.228±0.074 vs. 0.165±0.062, P<0.001). Similarly, the VD at the macula was also greater in controls than glaucoma patients (superficial retina capillary plexus: 0.115±0.016 vs. 0.088±0.027, P<0.001; deep retina capillary plexus: 0.233±0.027 vs. 0.136±0.073, P<0.001; outer retinal capillary plexus: 0.190±0.057 vs. 0.136±0.105, P=0.036; and choriocapillaris: 0.225±0.053 vs. 0.153±0.068, P<0.001. The AUROC was highest for optic disc radial peripapillary capillary (0.96), followed by nerve head (0.92) and optic disc choroid (0.76). At the macula, the AUROC was highest for deep retina (0.86), followed by choroid (0.84), superficial retina (0.81), and outer retina (0.72). Conclusions: Microvascular density of the optic disc and macula in glaucoma patients was reduced compared with healthy controls. VD of both optic disc and macula had a high diagnostic ability in differentiating healthy and glaucoma eyes.
Endoscopic cyclophotocoagulation may have a treatment role in Asian patients with glaucoma. The success rate appears poorer than previously reported in Caucasian populations. The treatment effect appeared to wane between 18 and 24 months post-treatment.
Cataracts, not pupil size, cause significant underestimation of RNFL measurements in both Cirrus and Stratus OCT. The extent of influence exerted does not appear different between the two instruments. Reproducibility of each machine appears to be affected differently. Mydriasis is required to achieve excellent reproducibility with Cirrus OCT, and media clarity is required with Stratus OCT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.