We did not reproduce the results of previous studies that reported a lower incidence of anesthesia awareness with BIS monitoring, and the use of the BIS protocol was not associated with reduced administration of volatile anesthetic gases. Anesthesia awareness occurred even when BIS values and ETAG concentrations were within the target ranges. Our findings do not support routine BIS monitoring as part of standard practice. (ClinicalTrials.gov number, NCT00281489 [ClinicalTrials.gov].).
In this study, the probability of early vein graft occlusion was increased by aprotinin, but this outcome was promoted by multiple risk factors for graft occlusion.
A conflicting anesthetic management was suggested by the simultaneous BIS readings 10.7% of the time. These results suggest that BISxp does not always provide a reproducible single number. Anesthesia providers should not rely exclusively on the BIS reading when assessing depth of anesthesia.
Catheter electrical ablation of ventricular tachycardia (VT) was attempted in 33 patients who had recurrent unimorphic VT refractory to 3.7 1.2 (mean + SD) antiarrhythmic drugs. Their mean age was 56 + 14 years. Twenty-two patients had coronary artery disease, six had other types of heart disease, and five had no structural heart disease. The mean left ventricular ejection fraction was 0.34 + 0.17. Thirty patients had only one documented morphologic type of spontaneous VT, whereas three patients had more than one. One to four shocks of 100 to 300 J each were delivered to the endocardial exit site of VT, as identified by endocardial activation mapping and pace-mapping. In each patient endocardial activation at the exit site of VT preceded the onset of the QRS complex (mean activation time -50 30 msec). Pace-mapping was possible in 26 patients, and in all but two patients the QRS complexes during VT and during pacing at the exit site of VT were very similar in at least 10 of 12 electrocardiographic leads. In 29 patients, shocks were delivered between an endocardial electrode (cathode) and a patch electrode on the chest wall (anode). Seven patients (including three who first received shocks using an external anode) whose VT originated in the septum received transseptal shocks between two electrodes positioned on either side of the septum. The procedure was successful in 15 patients (45%), who had no recurrence of VT either on no antiarrhythmic therapy or on the same regimen that was ineffective before ablation, over a follow-up period of 15.5 + 10 months (range 5 to 35). The ablation attempt was unsuccessful in 18 patients (55%). There were no significant differences in clinical and electrophysiologic variables between patients with and without a successful outcome. Seven nonfatal complications occurred in six patients: sustained nonclinical VT immediately after the shock, ventricular fibrillation on days S and 6 after ablation, neurologic deficits (n = 2), atrioventricular block (n = 2), and brachial artery thrombosis. In conclusion, catheter electrical ablation of VT
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.