Background
Diagnostic and patients’ management modifications induced by whole-body 18F-FDG-PET/CT had not been evaluated so far in prosthetic valve (PV) or native valve (NV) infective endocarditis (IE)-suspected patients.
Methods
140 consecutive patients in 8 tertiary care hospitals underwent 18F-FDG-PET/CT. ESC-2015-modified Duke criteria and patients’ management plan were established jointly by two experts before 18F-FDG-PET/CT. The same experts reestablished Duke classification and patients’ management plan immediately after qualitative interpretation of 18F-FDG-PET/CT. A 6-month final Duke classification was established.
Results
Among the 70 PV and 70 NV patients, 34 and 46 were classified as definite IE before 18F-FDG-PET/CT. Abnormal perivalvular 18F-FDG uptake was recorded in 67.2% PV and 24.3% NV patients respectively (p<0.001) and extracardiac uptake in 44.3% PV and 51.4% NV patients. IE classification was modified in 24.3% and 5.7% patients (p=0.005) (net reclassification index 20% and 4.3%). Patients’ managements were modified in 21.4% PV and 31.4% NV patients (p=0.25). It was mainly due to perivalvular uptake in PV patients and to extra-cardiac uptake in NV patients and consisted in surgery plan modifications in 7 patients, antibiotic plan modifications in 22 patients and both in 5 patients. Altogether, 18F-FDG-PET/CT modified classification and/or care in 40% of the patients (95% CI: 32-48), which was most likely to occur in those with a non-contributing echocardiography (p<0.001) or IE classified as possible at baseline (p=0.04), while there was no difference between NV and PV.
Conclusions
Systematic 18F-FDG-PET/CT did significantly and appropriately impact diagnostic classification and/or IE management in PV and NV-IE suspected patients.
Laboratory confirmation of heparin-induced thrombocytopenia (HIT) is of crucial importance and remains challenging and relies on platelet functional assays highlighting the presence of heparin-dependent platelet-activating antibodies in patient serum or plasma. Platelet functional assays using washed platelets include the 14C-serotonin release assay (SRA), usually described as the gold standard, and the heparin-induced platelet activation assay (HIPA). Since its first comparison with SRA there has been no additional published study regarding HIPA diagnostic performances compared to SRA. Aim of our retrospective study was to compare the concordance between HIPA and SRA in HIT suspected-patients with positive anti-PF4/heparin antibodies between October 2010 and October 2015. Fifty-five HIT-suspected patients who beneficiated from both HIPA and SRA were included. Positive and negative percent agreements were 83.8% (95% CI 68.0–93.8%) and 66.7% (95% CI 41.0–86.7%), respectively. Overall percent agreement was 78.2% (95% CI 65.0–92.2%). Agreement was higher in patients who underwent cardiopulmonary bypass with extracorporeal circulation circuit for cardiac surgery. We also confirm that the use of a minimum of 2 platelet donors to establish positive HIT diagnosis and 4 platelet donors to exclude HIT diagnosis allows obtaining a good agreement with SRA. Although HIPA and SRA were performed with different platelet donors and in different laboratories, HIPA had a good positive agreement with SRA for HIT diagnosis, showing that HIPA is a useful functional assay that does not require radioactivity and could be developed worldwide to improve HIT diagnosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.