Significant coronary artery disease (CAD) is a frequent finding in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI), and the management of these two conditions becomes of particular importance with the extension of the procedure to younger and lower-risk patients. Yet, the preprocedural diagnostic evaluation and the indications for treatment of significant CAD in TAVI candidates remain a matter of debate. In this clinical consensus statement, a group of experts from the European Association of Percutaneous Cardiovascular Interventions (EAPCI) in collaboration with the European Society of Cardiology (ESC) Working Group on Cardiovascular Surgery aims to review the available evidence on the topic and proposes a rationale for the diagnostic evaluation and indications for percutaneous revascularisation of CAD in patients with severe aortic stenosis undergoing transcatheter treatment. Moreover, it also focuses on commissural alignment of transcatheter heart valves and coronary re-access after TAVI and redo-TAVI.
Background Subjects with bicuspid aortic valve (BAV) have been excluded from transcatheter aortic valve re- placement (TAVR) randomized trials. Methods With this meta-analysis of observational studies we first compared TAVR outcomes of BAV vs. tricuspid aortic valve (TAV) patients, stratifying the results by device generation. Then, we looked for differences between balloon-expandable (BE) and self-expandable (SE) bioprostheses in BAV patients. Primary outcome was 30-day mortality. Secondary outcomes were 30-day stroke, moderate-severe paravalvular leakage, new pacemaker im- plantation, vascular complications and 1-year mortality. Results Thirteen studies (11,032 patients, 7291 TAV and 3741 BAV) and seven studies (706 patients, 367 treated with BE, 339 with SE valve) met inclusion criteria. Thirty-day (OR=1.13; 95% CI: 0.88–1.46, p=0.33) and 1-year mortality (OR=1.02; 95% CI: 0.77–1.37, p=0.87) were similar between patients receiving TAVR for BAV or TAV. Subjects treated for BAV were at higher risk of conversion to conventional surgery (OR=2.35; 95% CI: 1.30–4.23, p=0.005), implantation of a second valve (OR=2.06; 95% CI: 1.31–3.25; p=0.002), moderate/severe paravalvular leakage (PVL) (OR=1.67; 95% CI: 1.29–2.17; p=0.0001) and device failure (OR=1.26; 95% CI: 1.02–1.56; p=0.04). Rates of adverse events decreased significantly with the use of new-generation devices, but outcome differences remained consistent. BAV patients treated with BE vs. SE valves had similar 30-day and 1-year mortality, stroke and moderate-severe PVL. Balloon-expandable valves were associated with lower rates of a second valve and new pacemaker implantation but carried higher risk of annular rupture. Conclusions BAV patients treated with TAVR had similar 30-day and 1-year mortality as well as stroke and new pacemaker implantation rates compared to TAV subjects, but carried higher risk of moderate/severe PVL, conver- sion to surgery and device failure. Event rates significantly decreased with the use of new-generation devices, but TAVR still showed better procedural results in TAV compared to BAV. Funding Acknowledgement Type of funding source: None
BackgroundThe impact of transcatheter aortic valve replacement (TAVR) leaflet design on long-term device performance is still unknown. This study sought to compare the clinical and hemodynamic outcomes of intra- (IA) versus supra-annular (SA) TAVR designs up-to 10-years following implantation.MethodsConsecutive patients with at least 5-years follow-up following TAVR for severe symptomatic aortic stenosis from June 2007 to December 2016 were included. Bioprosthetic valve failure (BVF) and hemodynamic valve deterioration (HVD) were defined according to VARC-3 updated definitions and estimated using cumulative incidence function to account for the competing risk of death.ResultsA total of 604 patients (82 years; 53% female) were analyzed and divided into IA (482) and SA (122) groups. Overall survival rates at 10-years were similar (IA 15%, 95%CI: 10–22; SA 11%, 95%CI: 6–20; p = 0.21). Compared to the SA TAVR, mean transaortic gradients were significantly higher and increased over time in the IA group. IA TAVRs showed higher 10-year cumulative incidences of BVF (IA 8% vs. SA 1%, p = 0.02) and severe HVD (IA 5% vs. SA 1%, p = 0.05). The occurrence of BVF and HVD in the IA group occurred primarily in the smallest TAVR devices (20–23-mm). After excluding these sizes, the cumulative incidences of BVF (IA 5% vs. SA 1%, p = 0.40) and severe HVD (IA 2% vs. SA 1%, p = 0.11) were similar.ConclusionIn this study, TAVR leaflet design had no impact on survival at 10-years. IA devices showed higher transaortic gradients and cumulative incidences of HVD and BVF predominantly occurring in the smallest valve sizes.
BackgroundsAmong vascular closure devices (VCDs), the novel collagen plug-based MANTA VCD is the first designed for large bore percutaneous access. We aimed to assess the features and predictors of access-site vascular complications in an unselected trans-femoral transcatheter aortic valve replacement (TF-TAVR) population.MethodsPatients undergoing large bore arteriotomy closure with 18F MANTA VCD following TF-TAVR at a large tertiary care center from September 2019 to January 2021 were prospectively analyzed. Primary Outcome was the MANTA VCD access-site-related complications according to Valve Academic Research Consortium-3 (VARC) definitions. Its incidence and predictors were evaluated.ResultsEighty-eight patients (median age 82 years, 48% male, 3.3 median Society of Thoracic Surgeons score) undergoing TF-TAVR were included, mostly (63%) treated with a self-expandable device and with outer diameter sizes varied from 18F to 24-F. MANTA VCD technical success rate was 98%, while 10 patients (11%) experienced MANTA VCD access-site vascular complications which included 8% of minor complications and only to 2% of major events resulting in VARC type ≥2 bleeding. Vessel occlusion/stenosis (60%), perforation (20%), and pseudoaneurysm/dissection/hematoma (20%) occurred, but all were managed without surgical treatment. Independent predictors of failure were age (p = 0.04), minimum common femoral artery diameter (CFA) (p < 0.01), sheath-to-femoral-artery ratio (SFAR) (p < 0.01), and a lower puncture height (p = 0.03). A CFA diameter <7.1 mm with a SFAR threshold of 1.01 were associated with VCD failure.ConclusionsIn a more comers TF-TAVR population, MANTA VCD was associated with reassuring rates of technical success and major access-site vascular complications. Avoiding lower vessel size and less puncture site distance to CFA bifurcation might further improve outcomes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.