Small-angle X-ray scattering (SAXS) measurements of proteins in solution are becoming increasingly popular with biochemists and structural biologists owing to the presence of dedicated high-throughput beamlines at synchrotron sources. As part of the ESRF Upgrade program a dedicated instrument for performing SAXS from biological macromolecules in solution (BioSAXS) has been installed at the renovated BM29 location. The optics hutch has been equipped with new optical components of which the two principal elements are a fixed-exit double multilayer monochromator and a 1.1 m-long toroidal mirror. These new dedicated optics give improved beam characteristics (compared with the previous set-up on ID14-3) regarding the energy tunability, flux and focusing at the detector plane leading to reduced parasitic scattering and an extended s-range. User experiments on the beamline have been successfully carried out since June 2012. A description of the new BioSAXS beamline and the set-up characteristics are presented together with examples of obtained data.
The first phase of the ESRF beamline ID23 to be constructed was ID23-1, a tunable MAD-capable beamline which opened to users in early 2004. The second phase of the beamline to be constructed is ID23-2, a monochromatic microfocus beamline dedicated to macromolecular crystallography experiments. Beamline ID23-2 makes use of well characterized optical elements: a singlebounce silicon (111) monochromator and two mirrors in Kirkpatrick-Baez geometry to focus the X-ray beam. A major design goal of the ID23-2 beamline is to provide a reliable, easy-to-use and routine microfocus beam. ID23-2 started operation in November 2005, as the first beamline dedicated to microfocus macromolecular crystallography. The beamline has taken the standard automated ESRF macromolecular crystallography environment (both hardware and software), allowing users of ID23-2 to be rapidly familiar with the microfocus environment. This paper describes the beamline design, the special considerations taken into account given the microfocus beam, and summarizes the results of the first years of the beamline operation.
A new state-of-the art synchrotron beamline fully optimized for monochromatic X-ray diffraction at high pressure and high (or low) temperature is presented. In comparison with the old high-pressure beamline ID30, this new beamline exhibits outstanding performance in terms of photon flux and focusing capabilities. The main components of this new instrument will be described in detail and compared with the performance of beamline ID30. In particular, the choices in terms of X-ray source, X-ray optics, sample environment and detectors are discussed. The first results of the beamline commissioning are presented.
ID15A is a newly refurbished beamline at the ESRF devoted to operando and time‐resolved diffraction and imaging, total scattering and diffraction computed tomography. The beamline is optimized for rapid alternation between the different techniques during a single operando experiment in order to collect complementary data on working systems. The high available energy (up to 120 keV) means that even bulky and highly absorbing systems may be studied. The beamline is equipped with optimized focusing optics and a photon‐counting CdTe pixel detector, allowing for both unprecedented data quality at high energy and for very rapid triggered experiments. A large choice of imaging detectors and ancillary probes and sample environments is also available.
International audienceNewly available x-ray nanobeams in synchrotron radiation facilities open new research avenues in the nanosciences. However, a significant challenge is to efficiently concentrate, particularly for high-energy x-rays, a large photon flux into a very small focal spot. Here, we demonstrate for the first time, to the best of our knowledge, a sub-13-nm (FWHM) diffraction-limited x-ray focus size with 6 billion photons per second formed using elliptically figured mirrors operating at 33.6 keV. This is the smallest and brightest focus spot in this high-energy range. We report the results of an x-ray ptychography experiment to characterize the wavefront at the focus position. This offers new opportunities in multidisciplinary fields for x-ray microscopy techniques in which the focal spot size limits the resolution. (C) 2017 Optical Society of Americ
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.