Objectives. To evaluate virtual touch tissue imaging quantification (VTIQ) as a new elastography method concerning its intra- and interexaminer reliability and its ability to differentiate benign from malignant breast lesions in comparison to and in combination with ultrasound (US) B-mode breast imaging reporting and data system (BI-RADS) assessment. Materials and Methods. US and VTIQ were performed by two examiners in 103 women with 104 lesions. Intra- and interexaminer reliability of VTIQ was assessed. The area under the receiver operating curve (AUC), sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of BIRADS, VTIQ, and combined data were compared. Results. Fifty-four of 104 lesions were malignant. Intraexaminer reliability was consistent, and interexaminer agreement showed a strong positive correlation (r = 0.93). The mean VTIQ values in malignant lesions were significantly higher than those in benign (7.73 m/s ± 1.02 versus 4.46 m/s ± 1.87; P < 0.0001). The combination of US-BIRADS with the optimal cut-off for clinical decision making of 5.18 m/s yielded a sensitivity of 98%, specificity of 82%, PPV of 86%, and NPV of 98%. The combination of BIRADS and VTIQ led to improved test validity. Conclusion. VTIQ is highly reliable and reproducible. There is a significant difference regarding the mean maximum velocity of benign and malignant lesions. Adding VTIQ to BIRADS assessment improves the specificity.
Lumpectomy specimens are commonly divided into six sides: superficial, deep, superior, inferior, medial, and lateral. Orienting stitches are placed on the specimen during surgery to allow reorientation by pathology. Despite those efforts, specimen disorientation may occur. The aim of this study was to assess the correlation in orientation between surgeons and pathologists. Lumpectomy specimens were routinely oriented. An additional Prolene suture was randomly placed by the surgeon on one side to be localized by pathology. The results were recorded and the disorientation rate calculated. Specimen size and presence of skin and/or muscle were also recorded. There were 122 lumpectomy specimens prospectively entered. Average specimen volume was 95.5 cm(3). Twenty-four specimens had segments of skin or muscle. The additional sutures were evenly divided between the six sides. The overall disorientation rate was 31.1% (95% confidence interval, 23.1-40.2).The side-specific disorientation rates were 43%, 40%, 35%, 29%, 28%, and 14% for the deep, superficial, lateral, medial, superior, and inferior surfaces, respectively (no statistical difference). Presence of skin or muscle on the specimen did not contribute to better orientation. Specimen volumes, however, were highly associated with orientation. Specimens of <20 cm(3) had a disorientation rate of 78%, while larger specimen had a disorientation rate of 20% (p < .001). Specimen orientation with stitches placed on two surfaces is associated with a high disorientation rate. Better orientation techniques are necessary to minimize the specimen disorientation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.