Background
Medical simulation is an emerging field for resident training. Three-dimensional printing has accelerated the development of models for spine surgical simulation. Previous models have utilized augmented infill ratios to simulate the density difference between cortical and cancellous bone; however, this does not fully account for differences in the material properties of these components of human vertebrae. In order to replicate the differences in both density and material characteristics for realistic spinal simulation, we created a three-dimensional model composed of multiple thermoplastic polymers.
Materials and methods
Three lumbar vertebrae and 20 C2 vertebrae models using an experimental dual material fabrication method were printed on an Ultimaker S5 3D printer. Assessment of model integrity during instrumentation as well as user tactile feedback were points of interest to determine prototype viability for educational and biomechanical use. The experimental cohort was compared with a control cohort consisting of a single material print, resin print, and polyurethane mold.
Results
Based on tactile feedback, the experimental dual material print (polylactic acid [PLA]/polyvinyl alcohol [PVA]) more accurately represented the sensation of in vivo instrumentation during pedicle probing, pedicle tapping, and screw placement. There were no instrumentation or material failures in the PLA/PVA experimental model cohort.
Conclusions
This feasibility study indicates that multiple material printing using PLA and PVA is a viable method to replicate the cortico-cancellous interface in vertebral models. This concept and design using our unique infill algorithm have not been yet reported in the medical literature. Further educational and biomechanical testing on our design is currently underway to establish this printing method as a new standard for spinal biomimetic modeling.
Background Three-dimensional (3D) printing is a growing practice in the medical community for patient care and trainee education as well as production of equipment and devices. The development of functional models to replicate physiologic systems of human tissue has also been explored, although to a lesser degree. Specifically, the design of 3D printed phantoms that possess comparable biomechanical properties to human cervical vertebrae is an underdeveloped area of spine research. In order to investigate the functional uses of cervical 3D printed models for replicating the complex physiologic and biomechanical properties of the human subaxial cervical spine, our institution has created a prototype that accurately reflects these properties and provides a novel method of assessing spinal canal dimensions using simulated myelography. To our knowledge, this is the first 3D printed phantom created to study these parameters.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.