Technique failure varies widely across centers in Australia. A significant proportion of this variation is related to potentially modifiable center characteristics, including peritoneal dialysis center size, proportion of patients on peritoneal dialysis, and proportion of patients on peritoneal dialysis achieving target phosphate level.
Maximising the use of preclinical murine models of progressive kidney disease as test beds for therapies ideally requires kidney function to be measured repeatedly in a safe, minimally invasive manner. To date, most studies of murine nephropathy depend on unreliable markers of renal physiological function, exemplified by measuring blood levels of creatinine and urea, and on various end points necessitating sacrifice of experimental animals to assess histological damage, thus counteracting the principles of Replacement, Refinement and Reduction. Here, we applied two novel minimally invasive techniques to measure kidney function in SCID mice with adriamycin-induced nephropathy. We employed i) a transcutaneous device that measures the half-life of intravenously administered FITC-sinistrin, a molecule cleared by glomerular filtration; and ii) multispectral optoacoustic tomography, a photoacoustic imaging device that directly visualises the clearance of the near infrared dye, IRDye 800CW carboxylate. Measurements with either technique showed a significant impairment of renal function in experimental animals versus controls, with significant correlations with the proportion of scarred glomeruli five weeks after induction of injury. These technologies provide clinically relevant functional data and should be widely adopted for testing the efficacies of novel therapies. Moreover, their use will also lead to a reduction in experimental animal numbers.
In summary, several factors predicted early peritonitis in incident PD patients. Modified approaches to patient selection, training techniques, and prevention strategies should be considered in high-risk individuals.
♦ OBJECTIVE: Preservation of residual renal function (RRF) is associated with improved survival. The aim of the present study was to identify independent predictors of RRF and urine volume (UV) in incident peritoneal dialysis (PD) patients. ♦ METHODS: The study included incident PD patients who were ANZ trial participants. The primary and secondary outcomes were RRF and UV, respectively. Both outcomes were analyzed using mixed effects linear regression with demographic data in the first model and PD-related parameters included in a second model. ♦ RESULTS: The study included 161 patients (mean age 57.9 ± 14.1 years, 44% female, 33% diabetic, mean follow-up 19.5 ± 6.6 months). Residual renal function declined from 7.5 ± 2.9 mL/min/1.73 m at baseline to 3.3 ± 2.8 mL/min/1.73 m at 24 months. Better preservation of RRF was independently predicted by male gender, higher baseline RRF, higher time-varying systolic blood pressure (SBP), biocompatible (neutral pH, low glucose degradation product) PD solution, lower peritoneal ultrafiltration (UF) and lower dialysate glucose exposure. In particular, biocompatible solution resulted in 27% better RRF preservation. Each 1 L/day increase in UF was associated with 8% worse RRF preservation ( = 0.007) and each 10 g/day increase in dialysate glucose exposure was associated with 4% worse RRF preservation ( < 0.001). Residual renal function was not independently predicted by body mass index, diabetes mellitus, renin angiotensin system inhibitors, peritoneal solute transport rate, or PD modality. Similar results were observed for UV. ♦ CONCLUSIONS: Common modifiable risk factors which were consistently associated with preserved RRF and residual UV were use of biocompatible PD solutions and achievement of higher SBP, lower peritoneal UF, and lower dialysate glucose exposure over time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.