The atmospheric neutrino flavour ratio measured using a 1.52 kton-year exposure of Soudan 2 is found to be 0.72 +- 0.19 +0.05 -0.07 relative to the expected value from a Monte Carlo calculation. The possible background of interactions of neutrons and photons produced in muon interactions in the rock surrounding the detector has been investigated and is shown not to produce low values of the ratio.Comment: 18 pages, LaTeX, 3 ps files, and 2 style files. Submitted to Physics Letter
A protocol is presented for the calculation of monitor units (MU) for photon and electron beams, delivered with and without beam modifiers, for constant source-surface distance (SSD) and source-axis distance (SAD) setups. This protocol was written by Task Group 71 of the Therapy Physics Committee of the American Association of Physicists in Medicine (AAPM) and has been formally approved by the AAPM for clinical use. The protocol defines the nomenclature for the dosimetric quantities used in these calculations, along with instructions for their determination and measurement. Calculations are made using the dose per MU under normalization conditions, D 0 , that is determined for each user's photon and electron beams. For electron beams, the depth of normalization is taken to be the depth of maximum dose along the central axis for the same field incident on a water phantom at the same SSD, where D 0 = 1 cGy/MU. For photon beams, this task group recommends that a normalization depth of 10 cm be selected, where an energy-dependent D 0 ≤ 1 cGy/MU is required. This recommendation differs from the more common approach of a normalization depth of d m , with D 0 = 1 cGy/MU, although both systems are acceptable within the current protocol. For photon beams, the formalism includes the use of blocked fields, physical or dynamic wedges, and (static) multileaf collimation. No formalism is provided for intensity modulated radiation therapy calculations, although some general considerations and a review of current calculation techniques are included. For electron beams, the formalism provides for calculations at the standard and extended SSDs using either an effective SSD or an air-gap correction factor. Example tables and problems are included to illustrate the basic concepts within the presented formalism.
Lung CAD systems require the ability to classify a variety of pulmonary structures as part of the diagnostic process. The purpose of this work was to develop a methodology for fully automated voxel-by-voxel classification of airways, fissures, nodules, and vessels from chest CT images using a single feature set and classification method. Twenty-nine thin section CT scans were obtained from the Lung Image Database Consortium (LIDC). Multiple radiologists labeled voxels corresponding to the following structures: airways (trachea to 6th generation), major and minor lobar fissures, nodules, and vessels (hilum to peripheral), and normal lung parenchyma. The labeled data was used in conjunction with a supervised machine learning approach (AdaBoost) to train a set of ensemble classifiers. Each ensemble classifier was trained to detect voxels part of a specific structure (either airway, fissure, nodule, vessel, or parenchyma). The feature set consisted of voxel attenuation and a small number of features based on the eigenvalues of the Hessian matrix (used to differentiate structures by shape). When each ensemble classifier was composed of 20 weak classifiers, the AUC values for the airway, fissure, nodule, vessel, and parenchyma classifiers were 0.984 ± 0.011, 0.949 ± 0.009, 0.945 ± 0.018, 0.953 ± 0.016, and 0.931± 0.015 respectively. The strong results suggest that this could be an effective input to higher-level anatomical based segmentation models with the potential to improve CAD performance.
Deep underground muon events recorded by the Soudan 2 detector, located at a depth of 2100 meters of water equivalent, have been used to infer the nuclear composition of cosmic rays in the "knee" region of the cosmic ray energy spectrum. The observed muon multiplicity distribution favors a composition model with a substantial proton content in the energy region 8×10 5 −1.3×10 7 GeV/nucleus.
Oral mucositis can result in significant dysphagia, and is the most common dose-limiting acute toxicity in head and neck cancer patients receiving chemoradiotherapy. There is a critical need to determine the cellular and molecular mechanisms that underlie radiotherapy-associated discomfort in patients with mucositis. The objective was to induce oral mucositis in mice, using a clinical linear accelerator, and to quantify resultant discomfort, and characterize peripheral sensitization. A clinical linear accelerator was used to deliver ionizing radiation to the oral cavity of mice. Mucositis severity scoring, and various behavioral assays were performed to quantify bouts of orofacial wiping and scratching, bite force, gnawing behavior and burrowing activity. Calcium imaging was performed on neurons of the trigeminal ganglia. Glossitis was induced with a single fraction of at least 27 Gy. Body weight decreased and subsequently returned to baseline, in concert with development and resolution of mucositis, which was worst at day 10 and 11 postirradiation, however was resolved within another 10 days. Neither bite force, nor gnawing behavior were measurably affected. However, burrowing activity was decreased, and both facial wiping and scratching were increased while mice had visible mucositis lesions. Sensory nerves of irradiated mice were more responsive to histamine, tumor necrosis factor alpha and capsaicin. Radiation-induced glossitis is associated with hyper-reactivity of sensory neurons in the trigeminal ganglia of mice, and is accompanied by several behaviors indicative of both itch and pain. These data validate an appropriate model for cancer treatment related discomfort in humans.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.