High-dose dobutamine magnetic resonance tomography can be performed with a standard dobutamine/atropine stress protocol. Detection of wall motion abnormalities by DSMR yields a significantly higher diagnostic accuracy in comparison to DSE.
Background-With MRI, an index of myocardial perfusion reserve (MPRI) can be determined. We assessed the value of this technique for the noninvasive detection of coronary artery disease (CAD) in patients with suspected CAD. Methods and Results-Eighty-four patients referred for a primary diagnostic coronary angiography were examined with a 1.5 T MRI tomograph (Philips-ACS). For each heartbeat, 5 slices were acquired during the first pass of 0.025 mmol gadolinium-diethylenetriamine pentaacetic acid/kg body weight before and during adenosine vasodilation by using a turbo-gradient echo/echo-planar imaging-hybrid sequence. MPRI was determined from the alteration of the upslope of the myocardial signal intensity curves for 6 equiangular segments per slice. Receiver operating characteristics were performed for different criteria to differentiate ischemic and nonischemic segments. Prevalence of CAD was 51%. Best results were achieved when only the 3 inner slices were assessed and a threshold value of 1.1 was used for the second smallest value as a marker for significant CAD. This approach yielded a sensitivity of 88%, specificity of 90%, and accuracy of 89%. Conclusion-The determination of MPRI with MRI yields a high diagnostic accuracy in patients with suspected CAD.(Circulation. 2003;108:432-437.)
Background —Myocardial perfusion reserve can be noninvasively assessed with cardiovascular MR. In this study, the diagnostic accuracy of this technique for the detection of significant coronary artery stenosis was evaluated. Methods and Results —In 15 patients with single-vessel coronary artery disease and 5 patients without significant coronary artery disease, the signal intensity–time curves of the first pass of a gadolinium-DTPA bolus injected through a central vein catheter were evaluated before and after dipyridamole infusion to validate the technique. A linear fit was used to determine the upslope, and a cutoff value for the differentiation between the myocardium supplied by stenotic and nonstenotic coronary arteries was defined. The diagnostic accuracy was then examined prospectively in 34 patients with coronary artery disease and was compared with coronary angiography. A significant difference in myocardial perfusion reserve between ischemic and normal myocardial segments (1.08±0.23 and 2.33±0.41; P <0.001) was found that resulted in a cutoff value of 1.5 (mean minus 2 SD of normal segments). In the prospective analysis, sensitivity, specificity, and diagnostic accuracy for the detection of coronary artery stenosis (≥75%) were 90%, 83%, and 87%, respectively. Interobserver and intraobserver variabilities for the linear fit were low ( r =0.96 and 0.99). Conclusions —MR first-pass perfusion measurements yielded a high diagnostic accuracy for the detection of coronary artery disease. Myocardial perfusion reserve can be easily and reproducibly determined by a linear fit of the upslope of the signal intensity–time curves.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.