This study demonstrates that combined KLK4-7 expression by ovarian cancer cells promotes reduced integrin expression with consequently less cell-matrix attachment, and insensitivity to paclitaxel mediated by complex integrin and MAPK independent interactions, indicative of a malignant phenotype and disease progression suggesting a role for these KLKs in this process.
Purpose
The magnetic resonance imaging (MRI)‐Linac system combines a MRI scanner and a linear accelerator (Linac) to realize real‐time localization and adaptive radiotherapy for tumors. Given that the Australian MRI‐Linac system has a 30‐cm diameter of spherical volume (DSV) with a shimmed homogeneity of ±4.05 parts per million (ppm), a gradient nonlinearity (GNL) of <5% can only be assured within 15 cm from the system's isocenter. GNL increases from the isocenter and escalates close to and outside of the edge of the DSV. Gradient nonlinearity can cause large geometric distortions, which may provide inaccurate tumor localization and potentially degrade the radiotherapy treatment. In this study, we aimed to characterize and correct the geometric distortions both inside and outside of the DSV.
Methods
On the basis of phantom measurements, an inverse electromagnetic (EM) method was developed to reconstitute the virtual current density distribution that could generate gradient fields. The obtained virtual EM source was capable of characterizing the GNL field both inside and outside of the DSV. With the use of this GNL field information, our recently developed “GNL‐encoding” reconstruction method was applied to correct the distortions implemented in the k‐space domain.
Results
Both phantom and in vivo human images were used to validate the proposed method. The results showed that the maximal displacements within an imaging volume of 30 cm × 30 cm × 30 cm after using the fifth‐order spherical harmonic (SH) method and the proposed method were 6.1 ± 0.6 mm and 1.8 ± 0.6 mm, respectively. Compared with the fifth‐order SH‐based method, the new solution decreased the percentage of markers (within an imaging volume of 30 cm × 30 cm × 30 cm) with ≥1.5‐mm distortions from 6.3% to 1.3%, indicating substantially improved geometric accuracy.
Conclusions
The experimental results indicated that the proposed method could provide substantially improved geometric accuracy for the region outside of the DSV, when comparing with the fifth‐order SH‐based method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.