X-shooter is the first 2nd generation instrument of the ESO Very Large Telescope (VLT). It is a very efficient, single-target, intermediate-resolution spectrograph that was installed at the Cassegrain focus of UT2 in 2009. The instrument covers, in a single exposure, the spectral range from 300 to 2500 nm. It is designed to maximize the sensitivity in this spectral range through dichroic splitting in three arms with optimized optics, coatings, dispersive elements and detectors. It operates at intermediate spectral resolution (R ∼ 4000−17 000, depending on wavelength and slit width) with fixed échelle spectral format (prism cross-dispersers) in the three arms. It includes a 1.8 × 4 integral field unit as an alternative to the 11 long slits. A dedicated data reduction package delivers fully calibrated two-dimensional and extracted spectra over the full wavelength range. We describe the main characteristics of the instrument and present its performance as measured during commissioning, science verification and the first months of science operations.
Context. Absorption by molecules in the Earth's atmosphere strongly affects ground-based astronomical observations. The resulting absorption line strength and shape depend on the highly variable physical state of the atmosphere, i.e. pressure, temperature, and mixing ratio of the different molecules involved. Usually, supplementary observations of so-called telluric standard stars (TSS) are needed to correct for this effect, which is expensive in terms of telescope time. We have developed the software package molecfit to provide synthetic transmission spectra based on parameters obtained by fitting narrow ranges of the observed spectra of scientific objects. These spectra are calculated by means of the radiative transfer code LBLRTM and an atmospheric model. In this way, the telluric absorption correction for suitable objects can be performed without any additional calibration observations of TSS. Aims. We evaluate the quality of the telluric absorption correction using molecfit with a set of archival ESO-VLT/X-Shooter visible and near-infrared spectra. Methods. Thanks to the wavelength coverage from the U to the K band, X-Shooter is well suited to investigate the quality of the telluric absorption correction with respect to the observing conditions, the instrumental set-up, input parameters of the code, the signal-to-noise of the input spectrum, and the atmospheric profiles. These investigations are based on two figures of merit, I off and I res , that describe the systematic offsets and the remaining small-scale residuals of the corrections. We also compare the quality of the telluric absorption correction achieved with molecfit to the classical method based on a telluric standard star. Results. The evaluation of the telluric correction with molecfit shows a convincing removal of atmospheric absorption features. The comparison with the classical method reveals that molecfit performs better because it is not prone to the bad continuum reconstruction, noise, and intrinsic spectral features introduced by the telluric standard star. Conclusions. Fitted synthetic transmission spectra are an excellent alternative to the correction based on telluric standard stars. Moreover, molecfit offers wide flexibility for adaption to various instruments and observing sites.
Ultra-hot giant exoplanets receive thousands of times Earth’s insolation 1 , 2 . Their high-temperature atmospheres (>2,000 K) are ideal laboratories for studying extreme planetary climates and chemistry 3 – 5 . Daysides are predicted to be cloud-free, dominated by atomic species 6 and substantially hotter than nightsides 5 , 7 , 8 . Atoms are expected to recombine into molecules over the nightside 9 , resulting in different day-night chemistry. While metallic elements and a large temperature contrast have been observed 10 – 14 , no chemical gradient has been measured across the surface of such an exoplanet. Different atmospheric chemistry between the day-to-night (“evening”) and night-to-day (“morning”) terminators could, however, be revealed as an asymmetric absorption signature during transit 4 , 7 , 15 . Here, we report the detection of an asymmetric atmospheric signature in the ultra-hot exoplanet WASP-76b. We spectrally and temporally resolve this signature thanks to the combination of high-dispersion spectroscopy with a large photon-collecting area. The absorption signal, attributed to neutral iron, is blueshifted by −11±0.7 km s -1 on the trailing limb, which can be explained by a combination of planetary rotation and wind blowing from the hot dayside 16 . In contrast, no signal arises from the nightside close to the morning terminator, showing that atomic iron is not absorbing starlight there. Iron must thus condense during its journey across the nightside.
Aims. Based on a new set of sulphur abundances in very metal-poor stars and an improved analysis of previous data, we aim at resolving current discrepancies on the trend of S/Fe vs. Fe/H and thereby gain better insight into the nucleosynthesis of sulphur. The trends of Zn/Fe and S/Zn will also be studied. Methods. High resolution VLT/UVES spectra of 40 main-sequence stars with −3.3 < [Fe/H] < −1.0 are used to derive S abundances from the weak λ8694.6 S i line and the stronger λλ9212.9, 9237.5 pair of S i lines. For one star, the S abundance is also derived from the S i triplet at 1.046 µm recently observed with the VLT infrared echelle spectrograph CRIRES. Fe and Zn abundances are derived from lines in the blue part of the UVES spectra, and effective temperatures are obtained from the profile of the Hβ line. Conclusions. The trend of S/Fe vs. Fe/H corresponds to the trends of Mg/Fe, Si/Fe, and Ca/Fe and indicates that sulphur in Galactic halo stars has been made by α-capture processes in massive SNe. The observed scatter in S/Fe is much smaller than predicted from current stochastic models of the chemical evolution of the early Galaxy, suggesting that either the models or the calculated yields of massive SNe should be revised. We also examine the behaviour of S/Zn and find that departures from the solar ratio are significantly reduced at all metallicities if non-LTE corrections to the abundances of these two elements are adopted. This effect, if confirmed, would reduce the usefulness of the S/Zn ratio as a diagnostic of past star-formation activity, but would bring closer together the values measured in damped Lyman-alpha systems and in Galactic stars.Key words. stars: abundances -stars: atmospheres -Galaxy: halo -galaxies: abundances -galaxies: high-redshift IntroductionDespite several recent papers on sulphur abundances in Galactic stars, there is still no agreement on the trend of [S/Fe] Additional problems have been revealed by Takeda et al. (2005), who find that S abundances derived from the weak λ8694.6 S i line are systematically higher than S abundances derived from the stronger λλ9212.9, 9237.5 pair of lines when their new non-LTE corrections are applied.Article published by EDP Sciences and available at
On 4 July 2005, many observatories around the world and in space observed the collision of Deep Impact with comet 9P/Tempel 1 or its aftermath. This was an unprecedented coordinated observational campaign. These data show that (i) there was new material after impact that was compositionally different from that seen before impact; (ii) the ratio of dust mass to gas mass in the ejecta was much larger than before impact; (iii) the new activity did not last more than a few days, and by 9 July the comet's behavior was indistinguishable from its pre-impact behavior; and (iv) there were interesting transient phenomena that may be correlated with cratering physics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.