The Gafchromic EBT was recently introduced in film dosimetry for external beam therapy (EBT). The high spatial resolution, weak energy dependence, and near-tissue equivalence of EBT films make them suitable for measurement of dose distributions in radiotherapy, especially intensity-modulated radiation therapy (IMRT). Starting with a sensitometric curve and dose uncertainty relative to the flatbed scanner, the goal of this study was to find an efficient method of correcting for light scattering, and to compare dose distribution supplied by Gafchromic EBT with the distribution obtained with a 2D ion-chamber detector system. Light scattering was analyzed for different levels of dose, and was found to depend on the red-scale value as well as the position of the pixel on the scanner. Many "uniform" films were exposed at different levels of dose to create a two-dimensional matrix correction to take this effect into account. The dose distribution obtained for three clinical beams (10 x 10, 15 x 15 cm open fields and 12 x 12 cm wedge 60 degrees field) were in agreement with those supplied by the 2D array. Gamma index <1 (using 5 mm distance and 5% dose as constraints) for the three fields considered was reached in an average of 98% of the points.
The objective of this study was to assess the utility of CT-MRI image fusion software and compare both prostate volume and localization with CT and MRI studies. We evaluated the differences in clinical volumes in patients undergoing three-dimensional conformal radiation therapy for localized prostate cancer. After several tests performed to ensure the quality of image fusion software, eight patients suffering from prostate adenocarcinoma were submitted to CT and MRI studies in the treatment position within an immobilization device before the start of radiotherapy. The clinical target volume (CTV) (prostate plus seminal vesicles) was delineated on CT and MRI studies and image fusion was obtained from the superimposition of anatomical fiducial markers. A comparison of dose-volume histograms relative to CTV, rectum, bladder and femoral heads was performed for both studies. Image fusion showed a mean overestimation of CTV of 34% with CT compared with MRI. Along the anterior-posterior and superior-inferior direction, CTV was a mean 5 mm larger with CT study compared with MRI. The dose-volume histograms resulting from CT and MRI comparison showed that it is possible to spare a mean 10% of rectal volume and approximately 5% of bladder and femoral heads, respectively. This study confirmed an overestimation of CTV with CT images compared with MRI. Because this finding only allows a minimal sparing of organs at risk, considering the organ motion during each radiotherapy session and the excellent outcomes of prostate cancer treatment with CT based target identification, we are still reluctant to reduce the CTV to that identified by MRI.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.