We report on the production and implementation of 100 square panels 1 m x 1 m, based on the innovative approach of cold slumping of thin glass sheets. The more than 100 segments will cover around one half of the 240 m-square reflecting surface of the MAGIC II, a clone of the atmospheric Cherenkov telescope MAGIC I (with a single-dish 17 m diameter mirror) which is already operating since late 2003 at La Palma. The MAGIC II telescope will be completed by the end of 2008 and will operate in stereoscopic mode with MAGIC I. While the central part of the of the reflector is composed of by diamond milled Aluminum of 1m 2 area panels (following a design similar to that already used for MAGIC I), the outer coronas will be made of sandwiched glass segments. The glass panel production foresees the following steps: a) a thin glass sheet (1-2mm) is elastically deformed so as to retain the shape imparted by a master with convex profile -the radius of curvature is large, the sheet can be pressed against the master using vacuum suction -; b) on the deformed glass sheet a honeycomb structure that provides the needed rigidity is glued ; c) then a second glass sheet is glued on the top in order to obtain a sandwich; d) after on the concave side a reflecting coating (Aluminum) and a thin protective coating (Quartz) are deposited. The typical weight of each panel is about 12 kg and its resolution is better than 1 mrad at a level of diameter that contains the 90% of the energy reflected by the mirror; the areal cost of glass panels is ~2 k€ per 1m 2 . The technology based on cold slumping is a good candidate for the production of the primary mirrors of the telescopes forming the Cherenkov Telescope Array (CTA), the future large TeV observatory currently being studied in Europe. Details on the realization of MAGIC II new mirrors based on cold slumping glass will be presented.
The New Hard X-ray Mission (NHXM) is a space X-ray telescope project focused on the 0.2 to 80 keV energy band, coupled to good imaging, spectroscopic and polarimetry detectors. The mission is currently undergoing the Phase B study and it has been proposed to ESA as a small-size mission to be further studied in the context of the M3 call; even if the mission was not downselected for this call, its study is being continued by ASI. The required performance is reached with a focal length of 10 m and with four mirror modules, each of them composed of 70 NiCo electroformed mirror shells. The reflecting coating is a broadband graded multilayer film, and the focal plane is mounted onto an extensible bench. Three of the four modules are equipped with a camera made of two detectors positioned in series, a Silicon low energy detector covering the range 0.2 to 15 keV and a high energy detector based on CdTe sensitive from 10 keV up to 120 keV. The fourth module is dedicated to the polarimetry to be performed with enhanced imaging capabilities. In this paper the latest development in the design and manufacturing of the optics is presented. The design has been optimized in order to increase as much as possible the effective area in the high-energy band. The manufacturing of the mirror shells benefits from the latest development in the mandrel production (figuring and polishing), in the multilayer deposition and in the integration improvements.
The ATHENA X-ray observatory is a large-class ESA approved mission, with launch scheduled in 2028. The technology of silicon pore optics (SPO) was selected as baseline to assemble ATHENA's optic with hundreds of mirror modules, obtained by stacking wedged and ribbed silicon wafer plates onto silicon mandrels to form the Wolter-I configuration. In the current configuration, the optical assembly has a 3 m diameter and a 2 m 2 effective area at 1 keV, with a required angular resolution of 5 arcsec. The angular resolution that can be achieved is chiefly the combination of i) the focal spot size determined by the pore diffraction, ii) the focus degradation caused by surface and profile errors, iii) the aberrations introduced by the misalignments between primary and secondary segments, iv) imperfections in the co-focality of the mirror modules in the optical assembly. A detailed simulation of these aspects is required in order to assess the fabrication and alignment tolerances; moreover, the achievable effective area and the angular resolution depend on the mirror module design. Therefore, guaranteeing these optical performances requires: a fast design tool to find the most performing solution in terms of mirror module geometry and population, and an accurate point spread function simulation from local metrology and positioning information. In this paper, we present the results of simulations in the framework of ESA-financed projects (SIMPOSiuM, ASPHEA, SPIRIT) to prepare the ATHENA X-ray telescope: we deal with a detailed description of diffractive effects in an SPO mirror module, show ray-tracing results including mirror module misalignments, study in detail diffractive effects in different configurations, and assess the focal spot correspondence in X-rays and in the UV light, an important aspect to perform the mirror module alignment and integration. We also include a proton tracing simulation through a magnetic diverter in Halbach array configuration.
The realization of X-ray telescopes with imaging capabilities in the hard (> 10 keV) X-ray band requires the adoption of optics with shallow (< 0.25 deg) grazing angles to enhance the reflectivity of reflective coatings. On the other hand, to obtain large collecting area, large mirror diameters (< 350 mm) are necessary. This implies that mirrors with focal lengths ≥10 m shall be produced and tested. Full-illumination tests of such mirrors are usually performed with onground X-ray facilities, aimed at measuring their effective area and the angular resolution; however, they in general suffer from effects of the finite distance of the X-ray source, e.g. a loss of effective area for double reflection. These effects increase with the focal length of the mirror under test; hence a "partial" full-illumination measurement might not be fully representative of the in-flight performances. Indeed, a pencil beam test can be adopted to overcome this shortcoming, because a sector at a time is exposed to the X-ray flux, and the compensation of the beam divergence is achieved by tilting the optic. In this work we present the result of a hard X-ray test campaign performed at the BL20B2 beamline of the SPring-8 synchrotron radiation facility, aimed at characterizing the Point Spread Function (PSF) of a multilayer-coated Wolter-I mirror shell manufactured by Nickel electroforming. The mirror shell is a demonstrator for the NHXM hard X-ray imaging telescope (0.3 -80 keV), with a predicted HEW (Half Energy Width) close to 20 arcsec. We show some reconstructed PSFs at monochromatic X-ray energies of 15 to 63 keV, and compare them with the PSFs computed from post-campaign metrology data, self-consistently treating profile and roughness data by means of a method based on the Fresnel diffraction theory. The modeling matches the measured PSFs accurately.
The mirror assembly of the ESA New -Advanced Telescope for High-ENergy Astrophysics (New-ATHENA) will be the largest X-ray optics ever built. Indeed, its unprecedented size, mass and focal length create great difficulties for the ground calibration. The VERT-X project aims at developing an innovative calibration facility which will be able to accomplish to this extremely challenging task. The design is based on a 2.5 cm 2 parallel beam produced by an X-ray source positioned in the focus of a highly performing collimator. In order to cover the whole mirror, the beam will be accurately moved by a raster-scan with the capability to tilt up to 3 degrees in order to test the off-axis performance and the out of field stray-light. The whole system is enclosed in a cylindrical vacuum chamber about 20m high and with a diameter ranging from 7 to 4m. By design, VERT-X will be able to measure the New-ATHENA mirror half energy width (HEW) with a precision of 0.1", all over the field of view, with the source size, the collimator error and the raster scan tracking accuracy being the most important terms of the error budget. The VERT-X project, started in 2018, is financed by ESA and conducted by a consortium that includes INAF together with EIE, Media Lario, BCV Progetti and Apogeo Space. This paper presents the current state of the development and manufacturing of the most critical systems of the facility, namely the raster-scan mechanism and the source-collimator vertical assembly.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.