OBJECTIVES Elective treatment of aortic valve disease by transcatheter aortic valve replacement (TAVR) is becoming increasingly popular, even in patients with low risk and intermediate risk. Even patients with a bicuspid aortic valve (BAV) are increasingly considered eligible for TAVR. Permanent pacemaker implantation (PMI) is a known—frequently understated—complication of TAVR affecting 9–15% of TAVR patients with a potentially significant impact on longevity and quality of life. BAV patients are affected by the highest PMI rates, although they are frequently younger compared to their tricuspid peers. The aim of the study is to report benchmark data—from a high-volume centre (with a competitive TAVR programme) on PMI after isolated surgical aortic valve replacement (SAVR) in patients with BAV and tricuspid aortic valve (TAV). METHODS We performed a retrospective single-centre analysis on 4154 patients receiving isolated SAVRs (w/o concomitant procedures), between 2000 and 2019, of whom 1108 had BAV (27%). PMI rate and early- and long-term outcomes were analysed. For better comparability of these demographically unequal cohorts, 1:1 nearest neighbour matching was performed. RESULTS At the time of SAVR, BAV patients were on average 10 years younger than their TAV peers (59.7 ± 12 vs 69.3 ± 9; P < 0.001) and had less comorbidities; all relevant characteristics were equally balanced after statistical matching. Overall PMI rate was significantly higher in BAV patients (5.4% vs 3.8%; P = 0.03). BAV required PMI exclusively (100%) and TAV required predominately (96%) for persistent postoperative high-degree atrioventricular block. After matching, the PMI rate was similar (5.1% vs 4.4%, P = 0.5). In-hospital mortality in the matched cohort was 1% in both groups. Long-term survival was more favourable in BAV patients (94% vs 90% in TAV at 5 years; 89% vs 82% in TAV at 9 years; P = 0.013). CONCLUSIONS With SAVR, the overall incidence of PMI among BAV patients seems significantly higher; however, after propensity matching, no difference in PMI rates between BAV and TAV is evident. The PMI rate was remarkably lower among BAV patients after SAVR compared to the reported incidence after TAVR.
Background Four-dimensional cardiovascular magnetic resonance (CMR) flow assessment (4D flow) allows to derive volumetric quantitative parameters in mitral regurgitation (MR) using retrospective valve tracking. However, prior studies have been conducted in functional MR or in patients with congenital heart disease, thus, data regarding the usefulness of 4D flow CMR in case of a valve pathology like mitral valve prolapse (MVP) are scarce. This study aimed to evaluate the clinical utility of cine-guided valve segmentation of 4D flow CMR in assessment of MR in MVP when compared to standardized routine CMR and transthoracic echocardiography (TTE). Methods Six healthy subjects and 54 patients (55 ± 16 years; 47 men) with MVP were studied. TTE severity grading used a multiparametric approach resulting in mild/mild-moderate (n = 12), moderate-severe (n = 12), and severe MR (n = 30). Regurgitant volume (RVol) and regurgitant fraction (RF) were also derived using standard volumetric CMR and 4D flow CMR datasets with direct measurement of regurgitant flow (4DFdirect) and indirect calculation using the formula: mitral valve forward flow - left ventricular outflow tract stroke volume (4DFindirect). Results There was moderate to strong correlation between methods (r = 0.59–0.84, p < 0.001), but TTE proximal isovelocity surface area (PISA) method showed higher RVol as compared with CMR techniques (PISA vs. CMR, mean difference of 15.8 ml [95% CI 9.9–21.6]; PISA vs. 4DFindirect, 17.2 ml [8.4–25.9]; PISA vs. 4DFdirect, 27.9 ml [19.1–36.8]; p < 0.001). Only indirect CMR methods (CMR vs. 4DFindirect) showed moderate to substantial agreement (Lin’s coefficient 0.92–0.97) without significant bias (mean bias 1.05 ± 26 ml [− 50 to 52], p = 0.757). Intra- and inter-observer reliability were good to excellent for all methods (ICC 0.87–0.99), but with numerically lower coefficient of variation for indirect CMR methods (2.5 to 12%). Conclusions In the assessment of patients with MR and MVP, cine-guided valve segmentation 4D flow CMR is feasible and comparable to standard CMR, but with lower RVol when TTE is used as reference. 4DFindirect quantification has higher intra- and inter-technique agreement than 4DFdirect quantification and might be used as an adjunctive technique for cross-checking MR quantification in MVP.
Aims Cardiovascular magnetic resonance (CMR) imaging has long been a contraindication for patients with a cardiac implantable electronic device (CIED). Recent studies support the feasibility and safety for non-thoracic magnetic resonance imaging, but data for CMR are sparse. The aim of the current study was to determine the safety in patients with magnetic resonance (MR)-conditional or non-MR-conditional CIED and to develop a best practice approach. Methods and results All patients with a CIED undergoing CMR imaging (1.5 T) between April 2014 and April 2017 were included in the study. Devices were programmed according to the standardized protocol directly before and after the CMR examination. Follow-up interrogation was performed 6 months after CMR examination. Results were compared with a large, reference cohort of CIED patients not undergoing any MR examination. A total of 200 consecutive patients with a CIED (non-MR-conditional, n = 103) were included in the study. Directly after CMR imaging, one device failure (0.5%, battery status = end of service) was noted necessitating premature generator replacement. In three patients (2%) of pacemaker/implantable cardioverter-defibrillator (ICD) carriers a sustained ventricular tachycardia (VT) occurred during CMR imaging. Ten ICD showed a decrease in battery capacity immediately after CMR. Overall, the reference cohort showed comparable changes of CIED function during follow-up. Conclusion With adherence to a standardized protocol and established exclusion criteria CMR imaging could safely be performed in patients with a CIED. The potential risks of device malfunction necessitate the presence of a device trained individual during the entire CMR examination. If there is a history of VT storm the attendance of an experienced cardiologist, should be mandatory.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.