We report recent results on the performance of FLASH (Free Electron Laser in Hamburg) operating at a wavelength of 13.7 nm where unprecedented peak and average powers for a coherent EUV radiation source have been measured. In the saturation regime the peak energy approached 170 µJ for individual pulses while the average energy per pulse reached 70 µJ. The pulse duration was in the region of 10 femtoseconds and peak
Many scientific disciplines ranging from physics, chemistry and biology to material sciences, geophysics and medical diagnostics need a powerful X-ray source with pulse
The atomic level structure of the element fermium was investigated for the first time using a sample of 2.7x10(10) atoms of the isotope 255Fm with a half-life of 20.1 h. The atoms were evaporated from a filament and stored in the argon buffer gas of an optical cell. Atomic levels were sought by the method of resonance ionization spectroscopy using an excimer-dye-laser combination. Two atomic levels were found at wave numbers (25 099.8+/-0.2) and (25 111.8+/-0.2) cm(-1). Partial transition rates to the 5f(12)7s(2) (3)H(e)(6) ground state have been determined from their saturation characteristics. Multiconfiguration Dirac-Fock calculations suggest that the leading orders of these levels could be the 5f(12)7s7p (5)I(o)(6) and 5f(12)7s7p (5)G(o)(5) terms.
Extreme-ultraviolet to x-ray free-electron lasers (FELs) in operation for scientific applications are up to now single-user facilities. While most FELs generate around 100 photon pulses per second, FLASH at DESY can deliver almost two orders of magnitude more pulses in this time span due to its superconducting accelerator technology. This makes the facility a prime candidate to realize the next step in FELs-dividing the electron pulse trains into several FEL lines and delivering photon pulses to several users at the same time. Hence, FLASH has been extended with a second undulator line and self-amplified spontaneous emission (SASE) is demonstrated in both FELs simultaneously. FLASH can now deliver MHz pulse trains to two user experiments in parallel with individually selected photon beam characteristics. First results of the capabilities of this extension are shown with emphasis on independent variation of wavelength, repetition rate, and photon pulse length.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.