In multi-heterodyne interferometry, the non-ambiguous range (NAR) and measurement accuracy are limited by the generation of synthetic wavelengths. In this paper, we propose a multi-heterodyne interferometric absolute distance measurement based on dual dynamic electro-optic frequency combs (EOCs) to realize high-accuracy distance measurement with large scale. The modulation frequencies of the EOCs are synchronously and quickly controlled to perform dynamic frequency hopping with the same frequency variation. Therefore, variable synthetic wavelengths range from tens of kilometer to millimeter can be flexibly constructed, and traced to an atomic frequency standard. Besides, a phase-parallel demodulation method of multi-heterodyne interference signal is implemented based on FPGA. Experimental setup was constructed and absolute distance measurements were performed. Comparison experiments with He-Ne interferometers demonstrate an agreement within 8.6 µm for a range up to 45 m, with a standard deviation of 0.8 µm and a resolution better than 2 µm at 45 m. The proposed method can provide sufficient precision with large scale for many science and industrial applications, such as precision equipment manufacturing, space mission, length metrology.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.