DES-ISR identifies a high-risk cohort that is at an increased risk of events, in particular repeat revascularization, during long-term follow-up. The initial pattern of restenosis is the most important predictor of recurrent restenosis or the need for subsequent reintervention.
PurposeThe effect of Transcatheter Aortic Valve Implantation (TAVI) on left ventricular (LV) geometry and function was compared to traditional aortic replacement (AVR) by major surgery.Methods45 patients with aortic stenosis (AS) undergoing TAVI and 33 AVR were assessed by standard echo Doppler the day before and 2 months after the implantation. 2D echocardiograms were performed to measure left ventricular (LV) mass index (LVMi), relative wall thickness (RWT), ejection fraction (EF) and the ratio between transmitral E velocity and early diastolic velocity of mitral annulus (E/e’ ratio). Valvular-arterial impedance (Zva) was also calculated.ResultsAt baseline, the 2 groups were comparable for blood pressure, heart rate, body mass index mean transvalvular gradient and aortic valve area. TAVI patients were older (p<0.0001) and had greater LVMi (p<0.005) than AVR group. After 2 months, both the procedures induced a significant reduction of transvalvular gradient and Zva but the decrease of LVMi and RWT was significant greater after TAVI (both p<0.0001). E/e’ ratio and EF were significantly improved after both the procedure but E/e’ reduction was greater after TAVI (p<0.0001). TAVI exhibited greater percent reduction in mean transvalvular gradient (p<0.05), Zva (p<0.02), LVMi (p<0.0001), RWT (p<0.0001) and E/e’ ratio (p<0.0001) than AVR patients. Reduction of E/e’ ratio was positively related with reduction of RWT (r = 0.46, p<0.002) only in TAVI group, even after adjusting for age and percent reduction of Zva (r =0.43, p<0.005).ConclusionsTAVI induces a greater improvement of estimated LV filling pressure in comparison with major prosthetic surgery, due to more pronounced recovery of LV geometry, independent on age and changes of hemodynamic load.
TAVI with the CRS bioprosthesis is feasible and effective in appropriately selected cases of severe aortic regurgitation in native and bioprosthetic aortic valves.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.