BackgroundThe aims of this study were to evaluate the construct validity (known group), concurrent validity (criterion based) and test-retest (intra-rater) reliability of manual goniometers to measure passive hip range of motion (ROM) in femoroacetabular impingement patients and healthy controls.MethodsPassive hip flexion, abduction, adduction, internal and external rotation ROMs were simultaneously measured with a conventional goniometer and an electromagnetic tracking system (ETS) on two different testing sessions. A total of 15 patients and 15 sex- and age-matched healthy controls participated in the study.ResultsThe goniometer provided greater hip ROM values compared to the ETS (range 2.0-18.9 degrees; P < 0.001); good concurrent validity was only achieved for hip abduction and internal rotation, with intraclass correlation coefficients (ICC) of 0.94 and 0.88, respectively. Both devices detected lower hip abduction ROM in patients compared to controls (P < 0.01). Test-retest reliability was good with ICCs higher 0.90, except for hip adduction (0.82-0.84). Reliability estimates did not differ between the goniometer and the ETS.ConclusionsThe present study suggests that goniometer-based assessments considerably overestimate hip joint ROM by measuring intersegmental angles (e.g., thigh flexion on trunk for hip flexion) rather than true hip ROM. It is likely that uncontrolled pelvic rotation and tilt due to difficulties in placing the goniometer properly and in performing the anatomically correct ROM contribute to the overrating of the arc of these motions. Nevertheless, conventional manual goniometers can be used with confidence for longitudinal assessments in the clinic.
Spine stabilization exercises, in which patients are taught to perform isolated contractions of the transverses abdominus (TrA) during ''abdominal hollowing'', are a popular physiotherapeutic treatment for low back pain (LBP). Successful performance is typically judged by the relative increase in TrA thickness compared with that of the internal (OI) and external (OE) oblique muscles, measured using ultrasound. The day-to-day measurement error (imprecision) associated with these indices of preferential activation has not been assessed but is important to know since it influences the interpretation of changes after treatment. On 2 separate days, 14 controls and 14 patients with chronic LBP (cLBP) performed abdominal hollowing exercises in hook-lying, while M-mode ultrasound images superimposed with tissue Doppler imaging (TDI) data were recorded from the abdominal muscles (N = 5 on each side). The fascial lines bordering the TrA, OI and OE were digitized, and muscle thicknesses were calculated. The betweenday error (intra-observer) was expressed as the standard error of measurement, SEM; SEM as a percentage of the mean gave the coefficient of variation (CV). There were no significant between-day differences for the mean values of resting or maximal thickness for any muscle, in either group (P [ 0.05). The median SEM and CV of all thickness variables was 0.71 mm and 10.9%, respectively for the controls and 0.80 mm or 11.3%, respectively for the cLBP patients. For the contraction ratios (muscle thickness contracted/ thickness at rest), the CVs were 3-11% (controls) and 5-12% (patients). The CVs were unacceptably high (30-50%, both groups) for the TrA preferential activation ratio (TrA proportion of the total lateral abdominal muscle thickness when contracted minus at rest). In both the controls and patients, the precision of measurement of absolute muscle thickness and relative change in thickness during abdominal hollowing was acceptable, and commensurate with that typical of biological measurements. The TrA preferential activation ratio is too imprecise to be of clinical use. Knowledge of the SEM for these indices is essential for interpreting the clinical relevance of any changes observed following physiotherapy.
Combined knowledge of the functional kinematics and kinetics of the human body is critical for understanding a wide range of biomechanical processes including musculoskeletal adaptation, injury mechanics, and orthopaedic treatment outcome, but also for validation of musculoskeletal models. Until now, however, no datasets that include internal loading conditions (kinetics), synchronized with advanced kinematic analyses in multiple subjects have been available. Our goal was to provide such datasets and thereby foster a new understanding of how in vivo knee joint movement and contact forces are interlinked - and thereby impact biomechanical interpretation of any new knee replacement design. In this collaborative study, we have created unique kinematic and kinetic datasets of the lower limb musculoskeletal system for worldwide dissemination by assessing a unique cohort of 6 subjects with instrumented knee implants (Charité - Universitätsmedizin Berlin) synchronized with a moving fluoroscope (ETH Zürich) and other measurement techniques (including whole body kinematics, ground reaction forces, video data, and electromyography data) for multiple complete cycles of 5 activities of daily living. Maximal tibio-femoral joint contact forces during walking (mean peak 2.74 BW), sit-to-stand (2.73 BW), stand-to-sit (2.57 BW), squats (2.64 BW), stair descent (3.38 BW), and ramp descent (3.39 BW) were observed. Internal rotation of the tibia ranged from 3° external to 9.3° internal. The greatest range of anterio-posterior translation was measured during stair descent (medial 9.3 ± 1.0 mm, lateral 7.5 ± 1.6 mm), and the lowest during stand-to-sit (medial 4.5 ± 1.1 mm, lateral 3.7 ± 1.4 mm). The complete and comprehensive datasets will soon be made available online for public use in biomechanical and orthopaedic research and development.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.