Campbell, B. C.V. et al. (2019) Penumbral imaging and functional outcome in patients with anterior circulation ischaemic stroke treated with endovascular thrombectomy versus medical therapy: a meta-analysis of individual patient-level data.ABSTRACT Background: CT-perfusion (CTP) and MRI may assist patient selection for endovascular thrombectomy. We aimed to establish whether imaging assessments of ischaemic core and penumbra volumes were associated with functional outcomes and treatment effect.
Campbell, B. C. V. et al. (2018) Effect of general anaesthesia on functional outcome in patients with anterior circulation ischaemic stroke having endovascular thrombectomy versus standard care: a meta-analysis of individual patient data. Lancet Neurology, 17(1), pp. 47-53. (doi:10.1016/S1474-4422(17)30407-6) This is the author's final accepted version.There may be differences between this version and the published version. You are advised to consult the publisher's version if you wish to cite from it.http://eprints.gla.ac.uk/149670/ variables. An alternative approach using propensity-score stratification was also used. To account for between-trial variance we used mixed-effects modeling with a random effect for trial incorporated in all models. Bias was assessed using the Cochrane tool.Findings: Of 1764 patients in 7 trials, 871 were allocated to endovascular thrombectomy. After exclusion of 74 patients (72 who did not undergo the procedure and 2 with missing data on anaesthetic strategy), 236/797 (30%) of endovascular patients were treated under GA. At baseline, GA patients were younger and had shorter time to randomisation but similar pre-treatment clinical severity compared to non-GA. Endovascular thrombectomy improved functional outcome at 3 months versus standard care in both GA (adjusted common odds ratio (cOR) 1·52, 95%CI 1·09-2·11, p=0·014) and non-GA (adjusted cOR 2·33, 95%CI 1·75-3·10, p<0·001) patients. However, outcomes were significantly better for those treated under non-GA versus GA (covariate-adjusted cOR 1·53, 95%CI 1·14-2·04, p=0·004; propensitystratified cOR 1·44 95%CI 1·08-1·92, p=0·012). The risk of bias and variability among studies was assessed to be low.Interpretation: Worse outcomes after endovascular thrombectomy were associated with GA, after adjustment for baseline prognostic variables. These data support avoidance of GA whenever possible. The procedure did, however, remain effective versus standard care in patients treated under GA, indicating that treatment should not be withheld in those who require anaesthesia for medical reasons.
Funding:The HERMES collaboration was funded by an unrestricted grant from Medtronic to the University of Calgary.
Research in contextEvidence before this study between abolition of the thrombectomy treatment effect in MR CLEAN and no effect in THRACE. Three single-centre randomised trials of general anaesthesia versus conscious sedation found either no difference in functional outcome between groups or a slight benefit of general anaesthesia.
Added value of this studyThese data from contemporary, high quality randomised trials form the largest study to date of the association between general anesthesia and the benefit of endovascular thrombectomy versus standard care. We used two different approaches to adjust for baseline imbalances (multivariable logistic regression and propensity-score stratification). We found that GA for endovascular thrombectomy, as practiced in contemporary clinical care across a wide range of expert centres during the rand...
This initial experience highlights the fact that the importance of the technique with which new stroke thrombectomy devices are used may be as crucial as the device itself. The ADAPT technique is a simple and effective approach to acute ischemic stroke thrombectomy. Utilizing the latest generation of large bore aspiration catheters in this fashion has allowed us to achieve excellent clinical and angiographic outcomes.
This initial experience highlights the fact that the importance of the technique with which new stroke thrombectomy devices are used may be as crucial as the device itself. The ADAPT technique is a simple and effective approach to acute ischemic stroke thrombectomy. Utilizing the latest generation of large bore aspiration catheters in this fashion has allowed us to achieve excellent clinical and angiographic outcomes.
A tandem occlusion of the carotid artery at the bifurcation with a concomitant intracranial occlusion is a relatively rare and complex presentation of acute stroke. We have found that addressing the proximal lesion first and covering it with a stent prior to performing distal thrombectomy appears to be a safe and effective option in the treatment algorithm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.