Objective. To investigate the validity, reproducibility, and responsiveness of a simplified power Doppler ultrasound (PDUS) assessment of joint inflammation compared with a comprehensive 44-joint PDUS assessment in patients with rheumatoid arthritis (RA) who started therapy with a biologic agent. Methods. A total of 160 patients with active RA who started a biologic agent were prospectively recruited in 18 Spanish centers. The patients underwent clinical and laboratory assessment and blinded PDUS examination at baseline and 6 months. A PDUS examination of 128 synovial sites in 44 joints was performed. US synovitis and PD signal were semiquantitatively graded from 1 to 3 in all synovial sites. US count and index for synovitis and PD signal were obtained. PDUS intraobserver and interobserver reliability were evaluated. A process of data reduction based on the frequency of involvement of synovial sites by both synovitis and PD signal was conducted. Construct and discriminant validity of a simplified PDUS assessment was investigated. Results. A PDUS simplified assessment including 24 synovial sites from 12 joints detected 100% of patients with synovitis and 91% of patients with PD signal. There was a highly significant correlation between the 44-joint count and index for synovitis and PD signal and the 12-joint count and index for synovitis and PD signal at baseline and 6 months (r ؍ 0.84 -0.90, P < 0.0005). The smallest detectable difference was lower than the mean change in simplified PDUS variables. Conclusion. A 12-joint PDUS assessment of RA joint inflammation may be a valid, feasible method for multicenter monitoring of therapeutic response to biologic agents.
Summary
The pathogenesis of coronavirus disease 2019 (COVID-19) may be envisaged as the dynamic interaction between four vicious feedback loops chained or happening at once. These are the viral loop, the hyperinflammatory loop, the non-canonical renin-angiotensin system (RAS) axis loop, and the hypercoagulation loop. Severe acute respiratory syndrome (SARS)-coronavirus (CoV)-2 lights the wick by infecting alveolar epithelial cells (AECs) and downregulating the angiotensin converting enzyme-2 (ACE2)/angiotensin (Ang-1–7)/Mas1R axis. The viral feedback loop includes evading the host's innate response, uncontrolled viral replication, and turning on a hyperactive adaptative immune response. The inflammatory loop is composed of the exuberant inflammatory response feeding back until exploding in an actual cytokine storm. Downregulation of the ACE2/Ang-(1–7)/Mas1R axis leaves the lung without a critical defense mechanism and turns the scale to the inflammatory side of the RAS. The coagulation loop is a hypercoagulable state caused by the interplay between inflammation and coagulation in an endless feedback loop. The result is a hyperinflammatory and hypercoagulable state producing acute immune-mediated lung injury and eventually, adult respiratory distress syndrome.
Objective: We set out to analyze the incidence and predictive factors of pulmonary embolism (PE) in hospitalized patients with Covid-19. Methods: We prospectively collected data from all consecutive patients with laboratory-confirmed Covid-19 admitted to the Hospital de la Santa Creu i Sant Pau, a university hospital in Barcelona, between March 9 and April 15, 2020. Patients with suspected PE, according to standardized guidelines, underwent CT pulmonary angiography (CTPA). Results: A total of 1,275 patients with Covid-19 were admitted to hospital. CTPA was performed on 76 inpatients, and a diagnosis of PE was made in 32 (2.6% [95%CI 1.7-3.5%]). Patients with PE were older, and they exhibited lower PaO 2 :FiO 2 ratios and higher levels of D-dimer and C-reactive protein (CRP). They more often required admission to ICU and mechanical ventilation, and they often had longer hospital stays, although in-hospital mortality was no greater than in patients without PE. High CRP and D-dimer levels at admission (≥150 mg/L and ≥1,000 ng/ml, respectively) and a peak D-dimer ≥6,000 ng/ml during hospital stay were independent factors associated with PE. Prophylactic low molecular weight heparin did not appear to prevent PE. Increased CRP levels correlated with increased D-dimer levels and both correlated with a lower PaO 2 :FiO 2. Conclusions: The 2.6% incidence of PE in Covid-19 hospitalized patients is clearly high. Higher doses of thromboprophylaxis may be required to prevent PE, particularly in patients at increased risk, such as those with high levels of CRP and D-dimer at admission. These findings should be validated in future studies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.