BackgroundThe task of monitoring and managing the entire emergency department (ED) is becoming more important due to increasing pressure on the ED. Recently, dashboards have received the spotlight as health information technology to support these tasks.ObjectiveThis study aimed to describe the development of a real-time autonomous dashboard for the ED and to evaluate perspectives of clinical staff on its usability.MethodsWe developed a dashboard based on three principles—“anytime, anywhere, at a glance;” “minimal interruption to workflow;” and “protect patient privacy”—and 3 design features—“geographical layout,” “patient-level alert,” and “real-time summary data.” Items to evaluate the dashboard were selected based on the throughput factor of the conceptual model of ED crowding. Moreover, ED physicians and nurses were surveyed using the system usability scale (SUS) and situation awareness index as well as a questionnaire we created on the basis of the construct of the Situation Awareness Rating Technique.ResultsThe first version of the ED dashboard was successfully launched in 2013, and it has undergone 3 major revisions since then because of geographical changes in ED and modifications to improve usability. A total of 52 ED staff members participated in the survey. The average SUS score of the dashboard was 67.6 points, which indicates “OK-to-Good” usability. The participants also reported that the dashboard provided efficient “concentration support” (4.15 points), “complexity representation” (4.02 points), “variability representation” (3.96 points), “information quality” (3.94 points), and “familiarity” (3.94 points). However, the “division of attention” was rated at 2.25 points.ConclusionsWe developed a real-time autonomous ED dashboard and successfully used it for 5 years with good evaluation from users.
Background and objectives: To compare the first pass success (FPS) rate of the C-MAC video laryngoscope (C-MAC) and conventional Macintosh-type direct laryngoscopy (DL) during cardiopulmonary resuscitation (CPR) in the emergency department (ED). Materials and Methods: This study was a single-center, retrospective study conducted from April 2014 to July 2018. Patients were categorized into either the C-MAC or DL group, according to the device used on the first endotracheal intubation (ETI) attempt. The primary outcome was the FPS rate. A multiple logistic regression model was developed to identify factors related to the FPS. Results: A total of 573 ETIs were performed. Of the eligible cases, 263 and 310 patients were assigned to the C-MAC and DL group, respectively. The overall FPS rate was 75% (n = 431/573). The FPS rate was higher in the C-MAC group than in the DL group, but there was no statistically significant difference (total n = 431, 79% compared to 72%, p = 0.075). In the multiple logistic regression analysis, the C-MAC use had higher FPS rate (adjusted odds ratio: 1.80; 95% CI, 1.17–2.77; p = 0.007) than that of the DL use. Conclusions: The C-MAC use on the first ETI attempt during cardiopulmonary resuscitation in the emergency department had a higher FPS rate than that of the DL use.
The purpose of the present study was to evaluate the correlation among the trial number of in vitro fertilization (IVF), preoperative anxiety, and propofol requirement for conscious sedation. One hundred and twenty six Korean women undergoing oocyte retrieval were enrolled. The target-controlled infusion by the anesthesiologist was conducted with initial target propofol concentration of 2.5 microg/mL, which was manipulated until the sedation score 3 and desired clinical end point were achieved. A weak correlation was observed between visual analogue scale (VAS) anxiety and the dose of propofol required for the induction of conscious sedation (r=0.22, p=0.0192). A weak correlation was also found between VAS anxiety and the sedation time needed to reach the proper conscious sedation level for the procedure (r=0.181, p=0.0484). Multiple regression analysis showed that VAS anxiety, preoperative baseline prolactin level, and cortisol level had statistically significant effects on the propofol induction dose for target controlled conscious sedation. We concluded that the induction dose and time requirements for propofol in anesthesiologist-controlled conscious sedation be modified based on the preoperative anxiety level and the baseline blood concentration of stress hormone, cortisol and prolactin.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.