Objective to determine the anterior ethmoidal artery (AEA) anatomy and variations by computed tomography (CT) in adult and their relations to and presents new AEA classifications. Methods One hundred and fifty paranasal CT scans (300 sides) were included. Axial images were acquired with multiplanar reformates to obtain delicate details in coronal and sagittal planes. Results One hundred and forty-four AEAs canal (48%), 293 AEAs foramen (97.7%), and 229 AEAs sulcus could be detected (76.3%). The mean AEA intranasal length was 6.7 ± 1.27 mm (range: 4.24–10.6 mm). The mean angle between AEA and lamina papyracea was 105.49 ± 9.28 degrees (range: 76.41–129.76 degrees). Of them, 95.8% AEAs had an angle with lamina >90 degrees, while 4.2% had angle <90 degrees. The mean angle between AEA and lateral lamella of cribriform plate was 103.95 ± 13.08 degrees (range: 65.57–141.36 degrees). Of them, 87.5% AEAs had an angle >90 degrees and 12.5% had an angle <90 degrees. The mean distance between AEA and skull base was 1.37 ± 1.98 mm (range: 0–8.35 mm). The AEA types in relation to skull base was type 1 (0–2 mm from skull base; 64.6%), type 2 (2–4 mm; 22.2%), type 3 (4–6 mm; 11.1%), and type 4 (>6 mm; 2.1%). The mean distance between the AEA and frontal sinus ostium was 9.17 ± 4.72 mm (range: 0–25.36 mm). AEA classification according to distance from AEA to frontal sinus ostium was 17.4% type 1 (<5 mm), 41.7% type 2 (5–10 mm), 31.9% type 3 (10–15 mm), and 9% type 4 (>15 mm). Conclusion Provided AEA details improve surgeons' awareness of AEA variations in the endoscopic field and can help residents in training.
Background Anterior knee pain (AKP) is a problematic complaint, considered to be the most frequent cause of orthopedic consultancy for knee problems. This study aimed to highlight diagnostic accuracy of ultrasonography as a fast imaging technique in assessment of patients with AKP. Methods and results A prospective study was conducted on 143 patients with clinically confirmed AKP. All patients underwent ultrasonography and MRI examinations of the knee. The diagnostic accuracy of ultrasonography compared to MRI for evaluating different findings of possible causes of AKP were analyzed using receiver operating characteristic (ROC) curve and judged by area under curve (AUC). A total of 155 knees were included in the study; 26 knees showed no abnormalities, 19 knees showed positive MRI only, and 110 knees showed positive ultrasonography and MRI. Ultrasonography and MRI reported 11 different findings of possible causes of AKP or related to it. Joint effusion was the most common finding (38%) followed by trochlear cartilage defect (20.6%) and superficial infrapatellar subcutaneous edema (20%). The overall accuracy of ultrasonography was 85.3% sensitivity and 100% specificity. The ultrasonography provided the highest sensitivity (100%) in detecting bipartite patella, followed by 91.5% for joint effusion, and 87.5% for quadriceps tendinopathy. The ROC curve analysis of overall accuracy of ultrasonography showed an AUC of 0.93. The overall Kappa agreement between ultrasonography and MRI was good (k = 0.66). Conclusion Ultrasonography can be used to make a swift screening and assessment of painful anterior knee and as an alternative to MRI when it is unavailable or contraindicated.
Background: The diagnosis of sonographically indeterminate adnexal masses (AM) signifies a major challenge in clinical practice. Early detection and characterization have increased the need for accurate imaging evaluation before treatment. Purpose: To assess the validity and reproducibility of the ADNEX MR Scoring system in the diagnosis of sonographically indeterminate AM. Study Type: A prospective multicenter study. Population: In all, 531 women (mean age, 44 AE 11.2 years; range, 21-79 years) with 572 sonographically indeterminate AM. Field Strength/Sequence: 1.5T/precontrast T 1-weighted imaging (WI) fast spin echo (FSE) (in-phase and out-of-phase, with and without fat suppression); T 2-WI FSE; diffusion-WI single-shot echo planner with b-values of 0 and 1000 s/mm 2 ; and dynamic contrast-enhanced perfusion T 1-WI liver acquisition with volume acceleration (LAVA). Assessment: All MRI examinations were evaluated by three radiologists, and the AM were categorized into five scores based on the ADNEX MR Scoring system. Score 1: no AM; 2: benign AM; 3: probably benign AM; 4: indeterminate AM; 5: probably malignant AM. Histopathology and imaging follow-up were used as the standard references for evaluating the validity of the ADNEX MR Scoring system for detecting ovarian malignancy. Statistical Tests: Four-fold table test, kappa statistics (κ), and receiver operating characteristic (ROC) curve. Results: In all, 136 (23.8%) AM were malignant, and 436 (76.2%) were benign. Of the 350 AM classified as score 2, one (0.3%) was malignant; of the 62 AM classified as score 3, six (9.7%) were malignant; of the 73 AM classified as score 4, 43 (58.9%) were malignant; and of the 87 AM categorized as score 5, 86 (98.9%) were malignant. The best cutoff value for predicting malignant AM was score >3 with sensitivity and specificity of 92.9% and 94.9%, respectively. The interreader agreement of the ADNEX MR Scoring was very good (κ = 0.861).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.