The transportation accuracy of sealed radioisotope sources influences the therapeutic effect of high-dose-rate (HDR) brachytherapy. We have developed a pinhole imaging system for tracking an Ir-192 radiation source during HDR brachytherapy treatment. Our system consists of a dual-pinhole collimator, a scintillator, and a charge-coupled device (CCD) camera. We acquired stereo-shifted images to infer the source position in three dimensions using a dual pinhole collimator with 1.0 mm diameter pinholes. The CCD camera captured consecutive images of scintillation light that corresponds to the source positions every 2 s. The system automatically tracks scintillation light points using template-matching technique and measured the source positions therefrom. By integrating a series of CCD images, we could infer the source dwell time from the pixel values in the integrated image. We investigated the tracking accuracy of our system in monitoring simulated brachytherapy as it would be performed for cervical cancer by using water as a stand-in for human tissue. Ir-192 pellet was moved through a water tank using tandem and ovoid applicators. The CCD camera captured clear images of the scintillation light produced by the underwater Ir-192 source in conditions equivalent to common clinical situations. The differences between the measured and the reference 3D source positions and dwell times were 1.5 ± 0.7 mm and 0.8 ± 0.4 s, respectively. This system has the potential to track in vivo Ir-192 source in real time and may prove a useful tool for quality assurance during HDR brachytherapy treatments in clinical settings.
MRI-based gel dosimeters are attractive systems for the evaluation of complex dose distributions in radiotherapy. In particular, the nanocomposite Fricke gel dosimeter is one among a few dosimeters capable of accurately evaluating the dose distribution of heavy ion beams. In contrast, reduction of the scanning time is a challenging issue for the acquisition of three-dimensional volume data. In this study, we investigated a three-dimensional dose distribution measurement method for heavy ion beams using variable flip angle (VFA), which is expected to significantly reduce the MRI scanning time. Our findings clarified that the whole three-dimensional dose distribution could be evaluated within the conventional imaging time (20 min) and quality of one cross-section.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.