AimsOptical frequency domain imaging (OFDI) is a recently developed, light-based, high-resolution intravascular imaging technique. Intravascular ultrasound (IVUS) is a widely used, conventional imaging technique for guiding percutaneous coronary intervention (PCI). We aimed to demonstrate the non-inferiority of OFDI-guided PCI compared with IVUS-guided PCI in terms of clinical outcomes.Methods and resultsWe did a prospective, multicentre, randomized (ratio 1:1), active-controlled, non-inferiority study to compare head-to-head OFDI vs. IVUS in patients undergoing PCI with a second generation drug-eluting stent. The primary endpoint was target vessel failure defined as a composite of cardiac death, target-vessel related myocardial infarction, and ischaemia-driven target vessel revascularization until 12 months after the PCI. The major secondary endpoint was angiographic binary restenosis at 8 months. We randomly allocated 829 patients to receive OFDI-guided PCI (n = 414) or IVUS-guided PCI (n = 415). Target vessel failure occurred in 21 (5.2%) of 401 patients undergoing OFDI-guided PCI, and 19 (4.9%) of 390 patients undergoing IVUS-guided PCI, demonstrating non-inferiority of OFDI-guided PCI to IVUS-guided PCI (hazard ratio 1.07, upper limit of one-sided 95% confidence interval 1.80; Pnon-inferiority = 0.042). With 89.8% angiographic follow-up, the rate of binary restenosis was comparable between OFDI-guided PCI and IVUS-guided PCI (in-stent: 1.6% vs. 1.6%, P = 1.00; and in-segment: 6.2% vs. 6.0%, P = 1.00).ConclusionThe 12-month clinical outcome in patients undergoing OFDI-guided PCI was non-inferior to that of patients undergoing IVUS-guided PCI. Both OFDI-guided and IVUS-guided PCI yielded excellent angiographic and clinical results, with very low rates of 8-month angiographic binary restenosis and 12-month target vessel failure.Clinical registrationClinicalTrials.gov, number NCT01873027.
One-year clinical and angiographic outcome after BES implantation was noninferior to and not different from that after EES implantation in a mostly stable coronary artery disease population. One-year clinical outcome after both BES and EES use was excellent, with a low rate of TLR and extremely low rate of stent thrombosis.
Six months of DAPT was not inferior to 18 months of DAPT following implantation of a DES with a biodegradable abluminal coating. However, this result needs to be interpreted with caution given the open-label design and wide noninferiority margin of the present study. (Nobori Dual Antiplatelet Therapy as Appropriate Duration [NIPPON]; NCT01514227).
on behalf of the RESET InvestigatorsBackground-Several recent randomized trials comparing everolimus-eluting stent (EES) and sirolimus-eluting stent (SES) reported similar outcomes. However, only 1 trial was powered for a clinical end point, and no trial was powered for evaluating target-lesion revascularization. Methods and Results-Randomized Evaluation of Sirolimus-eluting versus Everolimus-eluting stent Trial is a prospective multicenter randomized open-label trial comparing EES with SES in Japan. The trial was powered for evaluating noninferiority of EES relative to SES in terms of target-lesion revascularization. From February and July 2010, 3197 patients were randomly assigned to receive either EES (1597 patients) or SES (1600 patients). At 1 year, the primary efficacy end point of target-lesion revascularization occurred in 65 patients (4.3%) in the EES group and in 76 patients (5.0%) in the SES group, demonstrating noninferiority of EES to SES (P noninferiority Ͻ0.0001, and P superiority ϭ0.34). Cumulative incidence of definite stent thrombosis was low and similar between the 2 groups (0.32% versus 0.38%, Pϭ0.77). An angiographic substudy enrolling 571 patients (EES, 285 patients and SES, 286 patients) demonstrated noninferiority of EES relative to SES regarding the primary angiographic end point of in-segment late loss (0.06Ϯ0.37 mm versus 0.02Ϯ0.46 mm, P noninferiority Ͻ0.0001, and P superiority ϭ0.24) at 278Ϯ63 days after index stent implantation. Conclusions-One-year clinical and angiographic outcome after EES implantation was noninferior to and not different from that after SES implantation in a stable coronary artery disease population with relatively less complex coronary anatomy. One-year clinical outcome after both EES and SES use was excellent with a low rate of target-lesion revascularization and a very low rate of stent thrombosis. Clinical Trial Registration-URL: http://www.clinicaltrials.gov. Unique identifier: NCT01035450.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.