Background Effective contact tracing is labor intensive and time sensitive during the COVID-19 pandemic, but also essential in the absence of effective treatment and vaccines. Singapore launched the first Bluetooth-based contact tracing app—TraceTogether—in March 2020 to augment Singapore’s contact tracing capabilities. Objective This study aims to compare the performance of the contact tracing app—TraceTogether—with that of a wearable tag-based real-time locating system (RTLS) and to validate them against the electronic medical records at the National Centre for Infectious Diseases (NCID), the national referral center for COVID-19 screening. Methods All patients and physicians in the NCID screening center were issued RTLS tags (CADI Scientific) for contact tracing. In total, 18 physicians were deployed to the NCID screening center from May 10 to May 20, 2020. The physicians activated the TraceTogether app (version 1.6; GovTech) on their smartphones during shifts and urged their patients to use the app. We compared patient contacts identified by TraceTogether and those identified by RTLS tags within the NCID vicinity during physicians’ 10-day posting. We also validated both digital contact tracing tools by verifying the physician-patient contacts with the electronic medical records of 156 patients who attended the NCID screening center over a 24-hour time frame within the study period. Results RTLS tags had a high sensitivity of 95.3% for detecting patient contacts identified either by the system or TraceTogether while TraceTogether had an overall sensitivity of 6.5% and performed significantly better on Android phones than iPhones (Android: 9.7%, iPhone: 2.7%; P<.001). When validated against the electronic medical records, RTLS tags had a sensitivity of 96.9% and specificity of 83.1%, while TraceTogether only detected 2 patient contacts with physicians who did not attend to them. Conclusions TraceTogether had a much lower sensitivity than RTLS tags for identifying patient contacts in a clinical setting. Although the tag-based RTLS performed well for contact tracing in a clinical setting, its implementation in the community would be more challenging than TraceTogether. Given the uncertainty of the adoption and capabilities of contact tracing apps, policy makers should be cautioned against overreliance on such apps for contact tracing. Nonetheless, leveraging technology to augment conventional manual contact tracing is a necessary move for returning some normalcy to life during the long haul of the COVID-19 pandemic.
PurposeTo investigate the predictive factors for myopic macular degeneration (MMD) and progression in adults with myopia.MethodsWe examined 828 Malay and Indian adults (1579 myopic eyes) with myopia (spherical equivalent (SE) ≤–0.5 dioptres) at baseline who participated in both baseline and 12-year follow-up visits of the Singapore Malay Eye Study and the Singapore Indian Eye Study. Eye examinations, including subjective refraction and axial length (AL) measurements, were performed. MMD was graded from fundus photographs following the Meta-Analysis for Pathologic Myopia classification. The predictive factors for MMD development and progression were assessed in adults without and with MMD at baseline, respectively as risk ratios (RR) using multivariable modified Poisson regression models. The receiver operating characteristic curve was used to visualise the performance of the predictive models for the development of MMD, with performance quantified by the area under the curve (AUC).ResultsThe 12-year cumulative MMD incidence was 10.3% (95% CI 8.9% to 12.0%) among 1504 myopic eyes without MMD at baseline. Tessellated fundus was a major predictor of MMD (RR=2.50, p<0.001), among other factors including age, worse SE and longer AL (all p<0.001). The AUC for prediction of MMD development was found to be 0.78 (95% CI 0.76 to 0.80) for tessellated fundus and increased significantly to an AUC of 0.86 (95% CI 0.84 to 0.88) with the combination of tessellated fundus with age, race, gender and SE (p<0.001). Older age (p=0.02), worse SE (p<0.001) and longer AL (p<0.001) were found to be predictors of MMD progression.ConclusionsIn adults with myopia without MMD, tessellated fundus, age, SE and AL had good predictive value for incident MMD. In adults with MMD, 1 in 10 eyes experienced progression over the same period. Older age, more severe myopia and longer AL were independent risk factors for progression.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.