Background—
The diagnosis of infective endocarditis (IE) in prosthetic valves and intracardiac devices is challenging because both the modified Duke criteria (DC) and echocardiography have limitations in this population. The added value of
18
F-fluorodeoxyglucose (
18
F-FDG) positron emission tomography (PET)/computed tomography (CT) and
18
F-FDG PET/CT angiography (PET/CTA) was evaluated in this complex scenario at a referral center with a multidisciplinary IE unit.
Methods and Results—
Ninety-two patients admitted to our hospital with suspected prosthetic valve or cardiac device IE between November 2012 and November 2014 were prospectively included. All patients underwent echocardiography and PET/CT, and 76 had cardiac CTA. PET/CT and echocardiography findings were evaluated and compared, with concordant results in 54% of cases (κ=0.23). Initial diagnoses with DC at admission, PET/CT, and DC+PET/CT were compared with the final diagnostic consensus reached by the IE Unit. DC+PET/CT enabled reclassification of 90% of cases initially classified as possible IE with DC and provided a conclusive diagnosis (definite/rejected) in 95% of cases. Sensitivity, specificity, and positive and negative predictive values were 52%, 94.7%, 92.9%, and 59.7% for DC; 87%, 92.1%, 93.6%, and 84.3% for PET/CT; and 90.7%, 89.5%, 92%, and 87.9% for DC+PET/CT. Use of PET/CTA yielded even better diagnostic performance values than PET/nonenhanced CT (91%, 90.6%, 92.8%, and 88.3% versus 86.4%, 87.5%, 90.2%, and 82.9%) and substantially reduced the rate of doubtful cases from 20% to 8% (
P
<0.001). DC+PET/CTA reclassified an additional 20% of cases classified as possible IE with DC+PET/nonenhanced CT. In addition, PET/CTA enabled detection of a significantly larger number of anatomic lesions associated with active endocarditis than PET/nonenhanced CT (
P
=0.006) or echocardiography (
P
<0.001).
Conclusions—
18
F-FDG PET/CT improves the diagnostic accuracy of the modified DC in patients with suspected IE and prosthetic valves or cardiac devices. PET/CTA yielded the highest diagnostic performance and provided additional diagnostic benefits.
Background
Patency of the false lumen in chronic aortic dissection (AD) is associated with aortic dilation and long-term aortic events. However, predictors of adverse outcomes in this population are limited. The aim of this study was to evaluate the relationship between aortic growth rate and false lumen flow dynamics and biomechanics in patients with chronic, patent AD.
Methods
Patients with a chronic AD with patent false lumen in the descending aorta and no genetic connective tissue disorder underwent an imaging follow-up including a contrast-enhanced 4D flow cardiovascular magnetic resonance (CMR) protocol and two consecutive computed tomography angiograms (CTA) acquired at least 1 year apart. A comprehensive analysis of anatomical features (including thrombus quantification), and false lumen flow dynamics and biomechanics (pulse wave velocity) was performed.
Results
Fifty-four consecutive patients with a chronic, patent false lumen in the descending aorta were included (35 surgically-treated type A AD with residual tear and 19 medically-treated type B AD). Median follow-up was 40 months. The in-plane rotational flow, pulse wave velocity and the percentage of thrombus in the false lumen were positively related to aortic growth rate (p = 0.006, 0.017, and 0.037, respectively), whereas wall shear stress showed a trend for a positive association (p = 0.060). These results were found irrespectively of the type of AD.
Conclusions
In patients with chronic AD and patent false lumen of the descending aorta, rotational flow, pulse wave velocity and wall shear stress are positively related to aortic growth rate, and should be implemented in the follow-up algorithm of these patients. Further prospective studies are needed to confirm if the assessment of these parameters helps to identify patients at higher risk of adverse clinical events.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.