After obtaining familial informed consent, between January 1996 and July 1997, 173 children (5 to 15 years old) with sickle cell disease were enrolled in a prospective multicenter study using blood screening, transcranial Doppler ultrasonography (n = 143), cerebral magnetic resonance imaging (n = 144), and neuropsychologic performance evaluation (n = 156) (Wechsler Intelligence tests WISC-III, WIPPSI-R), which were also performed in 76 sibling controls (5 to 15 years old). Among the 173 patients with sickle cell disease (155 homozygous for hemoglobin SS, 8 sickle cell beta0 thalassemia, 3 sickle cell beta+ thalassemia, 7 sickle cell hemoglobin C disease SC), 12 (6.9%) had a history of overt stroke, and the incidence of abnormal transcranial Doppler ultrasonography (defined as mean middle cerebral artery velocity > 200 cm/sec or absent) was 8.4% in the overall study population and 9.6% in patients with homozygous sickle cell anemia The silent stroke rate was 15%. Significantly impaired cognitive functioning was observed in sickle cell disease patients with a history of stroke (Performance IQ and Full Scale IQ), but also in patients with silent strokes (Similarities, Vocabulary, and Verbal Comprehension). However, infarcts on magnetic resonance imaging were not the only factors of cognitive deficit: Verbal IQ, Performance IQ, and Full Scale IQ were strongly impaired in patients with severe chronic anemia (hematocrit < or = 20%) and in those with thrombocytosis (platelets > 500 x 10(9)/L). Multivariate logistic regression analysis showed that abnormal magnetic resonance imaging (odds ratio [OR] = 2.76) (P = .047), hematocrit < or =20% (OR = 5.85) (P = .005), and platelets > 500 x 10(9)/L (OR = 3.99) (P = .004) were independent factors of cognitive deficiency (Full Scale IQ < 75) in sickle cell disease patients. The unfavorable effect of low hematocrit has already been suggested, but this is the first report concerning an effect of thrombocytosis and showing that silent stroke alone is not a factor of cognitive deficit when not associated with low hematocrit or thrombocytosis. The effect of hydroxyurea, which is known to increase hematocrit and decrease platelet count, on cognitive functioning of sickle cell patients should be evaluated prospectively.
Magnetic Resonance Imaging (MRI), a reference examination for cardiac morphology and function in humans, allows to image the cardiac right ventricle (RV) with high spatial resolution. The segmentation of the RV is a difficult task due to the variable shape of the RV and its ill-defined borders in these images. The aim of this paper is to evaluate several RV segmentation algorithms on common data. More precisely, we report here the results of the Right Ventricle Segmentation Challenge (RVSC), concretized during the MICCAI'12 Conference with an on-site competition. Seven automated and semi-automated methods have been considered, along them three atlas-based methods, two prior based methods, and two prior-free, image-driven methods that make use of cardiac motion. The obtained contours were compared against a manual tracing by an expert cardiac radiologist, taken as a reference, using Dice metric and Hausdorff distance. We herein describe the cardiac data composed of 48 patients, the evaluation protocol and the results. Best results show that an average 80% Dice accuracy and a 1cm Hausdorff distance can be expected from semi-automated algorithms for this challenging task on the datasets, and that an automated algorithm can reach similar performance, at the expense of a high computational burden. Data are now publicly available and the website remains open for new submissions (http://www.litislab.eu/rvsc/).
Transcatheter aortic valve replacement (TAVR) is a minimally invasive alternative to conventional aortic valve replacement in symptomatic patients with severe aortic stenosis and contraindications to surgery. The procedure has shown to improve patient's quality of life and prolong short-and mid-term survival in high-risk individuals, becoming a widely accepted therapeutic option which has been integrated into current clinical guidelines for the management of valvular heart disease. Nevertheless, not every patient at high-risk for surgery is a good candidate for TAVR. Besides clinical selection, which is usually established by the Heart Team, certain technical and anatomic criteria must be met as, unlike in surgical valve replacement, annular sizing is not performed under direct surgical evaluation but on the basis of non-invasive imaging findings. Present consensus document was outlined by a working group of researchers from the European Society of Cardiovascular Radiology (ESCR) and aims to provide guidance on the utilisation of CT and MR imaging prior to TAVR. Particular relevance is given to the technical requirements and standardisation of the scanning protocols which have to be tailored to the remarkable variability of the scanners currently utilised in clinical practice; recommendations regarding all required pre-procedural measurements and medical reporting standardisation have been also outlined, in order to ensure quality and consistency of reported data and terminology. Key Points • To provide a reference document for CT and MR acquisition techniques, taking into account the significant technological variation of available scanners. • To review all relevant measurements that are required and define a step-by-step guided approach for the measurements of different structures implicated in the procedure. • To propose a CT/MR reporting template to assist in consistent communication between various sites and specialists involved in the procedural planning.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.