Background. White-coat hypertension (HT), masked HT, HT with white-coat effect, and masked uncontrolled HT are well-recognized problems of over- and undertreatment of high blood pressure in real-life practice. However, little is known about the true prevalence in Thailand. Objectives. To examine the prevalence and characteristics of each HT subtype defined by mean home blood pressure (HBP) and clinic blood pressure (CBP) using telemonitoring technology in Thai hypertensives. Methods. A multicenter, observational study included adult hypertensives who had been diagnosed for at least 3 months based on CBP without the adoption of HBP monitoring. All patients were instructed to manually measure their HBP twice a day for the duration of at least one week using the same validated automated, oscillometric telemonitoring devices (Uright model TD-3128, TaiDoc Corporation, Taiwan). The HBP, CBP, and baseline demographic data were recorded on the web-based system. HT subtypes were classified according to the treatment status, CBP (≥or <140/90 mmHg), and mean HBP (≥or <135/85 mmHg) into the following eight subtypes: in nonmedicated hypertensives, there are four subtypes that are normotension, white-coat HT, masked HT, and sustained HT; in treated hypertensives, there are four subtypes that are well-controlled HT, HT with white-coat effect, masked uncontrolled HT, and sustained HT. Results. Of the 1,184 patients (mean age 58 ± 12.7 years, 59% women) from 46 hospitals, 1,040 (87.8%) were taking antihypertensive agents. The majority of them were enrolled from primary care hospitals (81%). In the nonmedicated group, the prevalence of white-coat and masked HT was 25.7% and 7.0%, respectively. Among the treated patients, the HT with white-coat effect was found in 23.3% while 46.7% had uncontrolled HBP (a combination of the masked uncontrolled HT (9.6%) and sustained HT (37.1%)). In the medicated older subgroup (n = 487), uncontrolled HBP was more prevalent in male than in female (53.6% vs. 42.4%, p=0.013). Conclusions. This is the first nationwide study in Thailand to examine the prevalence of HT subtypes. Almost one-fourth had white-coat HT or HT with white-coat effect. Approximately half of the treated patients especially in the older males had uncontrolled HBP requiring more intensive interventions. These results emphasize the role of HBP monitoring for appropriate HT diagnosis and management. The cost-effectiveness of utilizing THAI HBPM in routine practice needs to be examined in the future study.
Background Despite numerous studies supporting the outperformance of ultrathin-strut bioresorbable polymer sirolimus-eluting stent (Orsiro SES, Biotronik AG), the generalizability of the study results remains unclear in the Asian population. We sought to evaluate the clinical outcomes of the Orsiro SES in unselected Thai population. Methods The Thailand Orsiro registry was a prospective, open-label clinical study evaluating all patients with obstructive coronary artery disease implanted with Orsiro SES. The primary endpoint was target lesion failure (TLF) at 12 months. TLF is defined as a composite of cardiac death, target vessel myocardial infarction (TVMI), emergent coronary artery bypass graft (CABG), and clinically driven target lesion revascularization (CD-TLR). Patients with diabetes, small vessels (≤ 2.75 mm), chronic total occlusions (CTOs), and acute myocardial infarction (AMI) were pre-specified subgroups for statistical analysis. Result A total of 150 patients with 235 lesions were included in the analysis. Half of the patients (53.3%) presented with AMI, and 24% had diabetes. Among 235 lesions, 93(39.4%) were small vessels, and 24(10.2%) were chronic total occlusions. The primary endpoint, TLF at 12 months, occurred in eight patients (5.3%), predominately caused by cardiac death. By contrast, the incidences of TVMI and CD-TLR were null. The outcomes in pre-specified subgroup were not different from the overall population (all p > 0.05). One definite late stent thrombosis(0.7%) was incidentally observed during primary percutaneous coronary intervention to the non-target vessel. Conclusion The safety and efficacy of the ultrathin strut sirolimus-eluting stent in unselected cases are confirmed in the Thailand Orsiro registry. Despite the high proportion of pre-specified high-risk subgroups, the excellent stent performance was consistent with the overall population. Trial Registration TCTR20190325001.
Hypertension remains a significant risk factor for major cardiovascular events worldwide. Poor adherence to treatment is extremely common in clinical practice, leading to uncontrolled hypertension. However, some patients with resistant hypertension still have uncontrolled blood pressure despite good medical compliance. A specific group of patients also develop adverse reactions to many blood pressure-lowering medications. These scenarios indicate that innovative strategies to lower blood pressure in challenging cases of hypertension are needed. The blood pressure-lowering efficacy of catheter-based renal denervation therapy to decrease sympathetic tone has been confirmed in many publications in recent years. Apart from both the invasiveness and the expensiveness of this technology, appropriate case selection to undergo this procedure is still developing. The utilization of renal denervation therapy for hypertension treatment in Thailand has lasted for 10 years with a good response in most cases. Currently, only certain interventionists at a few medical schools in Thailand can perform this procedure. However, more physicians are now interested in applying this technology to their patients. The Thai Hypertension Society Committee has reviewed updated information to provide principles for the appropriate utilization of renal denervation therapy. The blood pressure-lowering mechanism, efficacy, suitable patient selection, pre- and postprocedural assessment and procedural safety of renal denervation are included in this statement.
Background: The diagnosis of coronary artery disease (CAD) is one of the most common clinical issues that face medical practitioners. Myocardial ischemia can be noninvasively assessed with cardiovascular magnetic resonance imaging (CMRI), which has become an emerging modality. Objective: Determine the accuracy of dipyridamole stress CMRI by using stress and rest perfusion combined with delayed enhancement imaging for detecting CAD. Methods: Thirty-nine patients (24 men, 15 women; mean age 64±11.4 years) who had experienced prior myocardial infarction or had suspected CAD were enrolled. Dipyridamole stress CMRI with subsequent coronary angiography was performed within a mean time interval of 16 days (range: 1-30 days). The dipyridamole stress CMR protocol included stress and rest perfusion followed by delayed enhancement imaging. Per-vessel analysis was done according to 17-segment model recommendation by the American Heart Association. Results: Coronary angiography depicted significant coronary artery stenosis (>70% stenosis of major epicardial artery) in 26 patients (55 coronary arteries). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the combined stress and rest perfusion with delayed enhancement imaging for detection of significant coronary artery stenosis were 76-96%, 79-96%, 87-93%, 83-96%, and 85-95%, in left anterior descending, left circumflex, and right coronary arteries, respectively. Without delayed enhancement imaging, stress and rest perfusion produced slightly lower sensitivity (69-92%), specificity (73- 96%), positive predictive value (79-93%), negative predictive value (80-92%), and accuracy (79-92%). Conclusion: Dipyridamole stress CMRI combined with delayed enhancement imaging yielded high diagnostic accuracy for the detection of coronary artery disease. This modality allows the clinical application for detection of CAD in selected group of patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.