Debris is captured with filter-based embolic protection in the vast majority of patients undergoing TAVR. Tissue-derived material is found in 63% of cases and is more frequent with the use of balloon-expandable systems and more oversizing.
BackgroundCoronary artery perforation (CAP) is a potentially lethal complication of percutaneous coronary intervention. We report on the incidence, clinical characteristics, and management of iatrogenic coronary perforations based on an 11‐year single‐center experience.Methods and ResultsFrom February 9, 2005, through November 20, 2016, 150 CAP cases were identified from our percutaneous coronary intervention database of 21 212 procedures (0.71%). Mean age of CAP patients was 66±11 years, and 62.7% were male. Treated lesion type was B2/C in 94.6%, and 31.3% were chronic total occlusions. Nonworkhorse guidewires were applied in 74.3%. CAP types were Ellis type I in 2.9%, Ellis type II in 40.4%, Ellis type III in 54.8%, and Ellis type III cavity spilling in 1.9%. CAP treatment was conservative (including prolonged balloon inflation) in 73.3%. Covered stents, coiling, and fat embolization were used in 24.0%, 0.7%, and 2.0%, respectively. Pericardiocentesis for tamponade was required for 72 patients (48.0%), of whom 28 were initially unrecognized. Twelve patients (12.7%) required emergency cardiac surgery to alleviate tamponade. Periprocedural myocardial infarction occurred in 34.0%, and in‐hospital all‐cause mortality was 8.0%. All‐cause mortality accrued to 10.7% at 30 days and 17.8% at 1 year.ConclusionsCAP is a rare complication of percutaneous coronary intervention, but morbidity and mortality are considerable. Early recognition and adequate management are of paramount importance.
Background:
Fractional flow reserve (FFR)-guided treatment has been demonstrated to improve percutaneous coronary intervention (PCI) results. However, little is known on the long-term impact of low post-PCI FFR.
Methods:
This is a large prospective all comers study evaluating the impact of post-PCI FFR on clinical outcomes. All patients undergoing successful PCI were eligible for enrollment. FFR measurements were performed immediately after PCI when the operator considered the angiographic result acceptable and final. No further action was undertaken based on the post-PCI result. Suboptimal post-PCI FFR was defined as FFR<0.90. The primary end point was major adverse cardiac events, a composite of cardiac death, any myocardial infarction, or any revascularization at 2-year follow-up. Secondary end points were target vessel revascularizations and stent thrombosis and the separate components of the primary end point.
Results:
A total of 1000 patients were enrolled. Post-PCI FFR was successfully measured in 1165 vessels from 959 patients. A poststenting FFR<0.90 was observed in 440 vessels (37.8%). A total of 399 patients had at least 1 vessel with FFR<0.90 post-PCI. At 2-year follow-up, a patient level analysis showed no association between post-PCI FFR and major adverse cardiac event (hazard ratio [HR], 1.08 [95% CI, 0.73–1.60],
P
=0.707), cardiac death (HR, 1.55 [95% CI, 0.72–3.36],
P
=0.261), any myocardial infarction (HR, 1.53 [95% CI, 0.78–3.02],
P
=0.217). A vessel level analysis showed a higher rate of target vessel revascularization (HR, 1.91 [95% CI, 1.06–3.44],
P
=0.030) and a tendency toward higher rate of stent thrombosis (HR, 2.89 [95% CI, 0.88–9.48],
P
=0.081) with final post-PCI FFR<0.90.
Conclusions:
Suboptimal post-PCI FFR has only a moderate impact on major adverse cardiac event but coronary arteries with a post-PCI FFR<0.90 have a higher rate of target vessel revascularization.
Aims:The haemodynamic effects of primary implantation of an intra-aortic balloon pump (IABP) versus inotropes in decompensated heart failure and low output (DHF-LO), but without an acute coronary syndrome, have not been investigated. We therefore aimed to investigate the effect of primary IABP implantation as compared to inotropes on haemodynamics in DHF-LO with no acute ischaemia.Methods and results: Patients (n=32) with DHF-LO despite IV diuretics were randomised to primary 50 mL IABP or inotropes (INO: enoximone or dobutamine). The primary endpoint was the improvement 2
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.