High-power, high-brightness electron beams are of interest for many applications, especially as drivers for free electron lasers and energy recovery linac light sources. For these particular applications, photoemission injectors are used in most cases, and the initial beam brightness from the injector sets a limit on the quality of the light generated at the end of the accelerator. At Cornell University, we have built such a high-power injector using a DC photoemission gun followed by a superconducting accelerating module. Recent results will be presented demonstrating record setting performance up to 65 mA average current with beam energies of 4-5 MeV. V
We present a detailed study of the six-dimensional phase space of the electron beam produced by the Cornell Energy Recovery Linac Photoinjector, a high-brightness, high repetition rate (1.3 GHz) DC photoemission source designed to drive a hard x-ray energy recovery linac (ERL). A complete simulation model of the injector has been constructed, verified by measurement, and optimized. Both the horizontal and vertical 2D transverse phase spaces, as well as the time-resolved (sliced) horizontal phase space, were simulated and directly measured at the end of the injector for 19 and 77 pC bunches at roughly 8 MeV. These bunch charges were chosen because they correspond to 25 and 100 mA average current if operating at the full 1.3 GHz repetition rate. The resulting 90% normalized transverse emittances for 19 ð77Þ pC=bunch were 0:23 AE 0:02 ð0:51 AE 0:04Þ m in the horizontal plane, and 0:14 AE 0:01 ð0:29 AE 0:02Þ m in the vertical plane, respectively. These emittances were measured with a corresponding bunch length of 2:1 AE 0:1 ð3:0 AE 0:2Þ ps, respectively. In each case the rms momentum spread was determined to be on the order of 10 À3 . Excellent overall agreement between measurement and simulation has been demonstrated. Using the emittances and bunch length measured at 19 pC=bunch, we estimate the electron beam quality in a 1.3 GHz, 5 GeV hard x-ray ERL to be at least a factor of 20 times better than that of existing storage rings when the rms energy spread of each device is considered. These results represent a milestone for the field of high-brightness, highcurrent photoinjectors.
The Cornell University energy recovery linac (ERL) photoinjector has recently demonstrated operation at 20 mA for approximately 8 hours, utilizing a multialkali photocathode deposited on a Si substrate. We describe the recipe for photocathode deposition, and will detail the parameters of the run. Post-run analysis of the photocathode indicates the presence of significant damage to the substrate, perhaps due to ion back-bombardment from the residual beam line gas. While the exact cause of the substrate damage remains unknown, we describe multiple surface characterization techniques (x-ray fluorescence spectroscopy, x-ray diffraction, atomic force, and scanning electron microscopy) used to study the interesting morphological and crystallographic features of the photocathode surface after its use for high current beam production. Finally, we present a simple model of crystal damage due to ion back-bombardment, which agrees qualitatively with the distribution of damage on the substrate surface.
A new high voltage photoemission gun has been constructed at Cornell University which features a segmented insulator and a movable anode, allowing the cathode-anode gap to be adjusted. In this work, we describe the gun's overall mechanical and high voltage design, the surface preparation of components, as well as the clean construction methods. We present high voltage conditioning data using a 50 mm cathode-anode gap, in which the conditioning voltage exceeds 500 kV, as well as at smaller gaps. Finally, we present simulated emittance results obtained from a genetic optimization scheme using voltage values based on the conditioning data. These results indicate that for charges up to 100 pC, a 30 mm gap at 400 kV has equal or smaller 100% emittance than a 50 mm gap at 450 kV, and also a smaller core emittance, when placed as the source for the Cornell energy recovery linac photoinjector with bunch length constrained to be <3 ps rms. For 100 pC up to 0.5 nC charges, the 50 mm gap has larger core emittance than the 30 mm gap, but conversely smaller 100% emittance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.