Deep phenotyping has been defined as the precise and comprehensive analysis of phenotypic abnormalities in which the individual components of the phenotype are observed and described. The three components of the Human Phenotype Ontology (HPO; www.human-phenotype-ontology.org) project are the phenotype vocabulary, disease-phenotype annotations and the algorithms that operate on these. These components are being used for computational deep phenotyping and precision medicine as well as integration of clinical data into translational research. The HPO is being increasingly adopted as a standard for phenotypic abnormalities by diverse groups such as international rare disease organizations, registries, clinical labs, biomedical resources, and clinical software tools and will thereby contribute toward nascent efforts at global data exchange for identifying disease etiologies. This update article reviews the progress of the HPO project since the debut Nucleic Acids Research database article in 2014, including specific areas of expansion such as common (complex) disease, new algorithms for phenotype driven genomic discovery and diagnostics, integration of cross-species mapping efforts with the Mammalian Phenotype Ontology, an improved quality control pipeline, and the addition of patient-friendly terminology.
BackgroundAs more inhaled corticosteroid (ICS) devices become available, there may be pressure for health-care providers to switch patients with asthma to cheaper inhaler devices. Our objective was to evaluate impact on asthma control of inhaler device switching without an accompanying consultation in general practice.MethodsThis 2-year retrospective matched cohort study used the UK General Practice Research Database to identify practices where ICS devices were changed without a consultation for ≥5 patients within 3 months. Patients 6–65 years of age from these practices whose ICS device was switched were individually matched with patients using the same ICS device who were not switched. Asthma control over 12 months after the switch was assessed using a composite measure including short-acting β-agonist and oral corticosteroid use, hospitalizations, and subsequent changes to therapy.ResultsA total of 824 patients from 55 practices had a device switch and could be matched. Over half (53%) of device switches were from dry powder to metered-dose inhalers. Fewer patients in switched than matched cohort experienced successful treatment based on the composite measure (20% vs. 34%) and more experienced unsuccessful treatment (51% vs. 38%). After adjusting for possible baseline confounding factors, the odds ratio for treatment success in the switched cohort compared with controls was 0.29 (95% confidence interval [CI], 0.19 to 0.44; p < 0.001) and for unsuccessful treatment was 1.92 (95% CI, 1.47 to 2.56; p < 0.001).ConclusionSwitching ICS devices without a consultation was associated with worsened asthma control and is therefore inadvisable.
This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.