BackgroundSupine recumbence has been widely performed to prevent post-lumbar puncture headache (PLPH). However, the optimal duration of supine recumbence is controversial. The aim of the study is to compare the occurrence of PLPH according to the duration of supine recumbence in patients with neurological disorders.MethodsA non-equivalent control/experimental pre-/post-test study design was used. Seventy consecutive patients were prospectively enrolled between July 2007 and July 2008. Thirty-five patients underwent supine recumbence for four hours after lumbar puncture (Group 1) and 35 patients underwent supine recumbence for one hour (Group 2).ResultsThe overall frequency of PLPH was 31.4%. The frequency of PLPH was not significantly different between the Group 1 (28.6%) and Group 2 (34.3%) (P = 0.607). In patients with PLPH, the median severity (P = 0.203) and median onset time of PLPH (P = 0.582) were not significantly different between the two groups. In a logistic regression analysis, the previous history of post-lumbar puncture headache was a significant risk factor for the occurrence of PLPH (OR = 11.250, 95% CI: 1.10-114.369, P = 0.041).ConclusionsOur study suggests that short duration (one hour) of supine recumbence may be as efficient as long duration (four hours) of supine recumbence to prevent PLPH.
Background and Purpose Decreasing the time delay for thrombolysis, including intravenous thrombolysis (IVT) with tissue plasminogen activator and intra-arterial thrombectomy (IAT), is critical for decreasing the morbidity and mortality of patients experiencing acute stroke. We aimed to decrease the in-hospital delay for both IVT and IAT through a multidisciplinary approach that is feasible 24 h/day. Methods We implemented the Stroke Alert Team (SAT) on May 2, 2016, which introduced hospital-initiated ambulance prenotification and reorganized in-hospital processes. We compared the patient characteristics, time for each step of the evaluation and thrombolysis, thrombolysis rate, and post-thrombolysis intracranial hemorrhage from January 2014 to August 2016. Results A total of 245 patients received thrombolysis (198 before SAT; 47 after SAT). The median door-to-CT, door-to-MRI, and door-to-laboratory times decreased to 13 min, 37.5 min, and 8 min, respectively, after SAT implementation (P<0.001). The median door-to-IVT time decreased from 46 min (interquartile range [IQR] 36–57 min) to 20.5 min (IQR 15.8–32.5 min; P<0.001). The median door-to-IAT time decreased from 156 min (IQR 124.5–212.5 min) to 86.5 min (IQR 67.5–102.3 min; P<0.001). The thrombolysis rate increased from 9.8% (198/2,012) to 15.8% (47/297; P=0.002), and the post-thrombolysis radiological intracranial hemorrhage rate decreased from 12.6% (25/198) to 2.1% (1/47; P=0.035). Conclusions SAT significantly decreased the in-hospital delay for thrombolysis, increased thrombolysis rate, and decreased post-thrombolysis intracranial hemorrhage. Time benefits of SAT were observed for both IVT and IAT and during office hours and after-hours.
Here, most patients experienced a severe respiratory compliance event during at least one of their procedures. Overall incidence was 29% and was more likely on subsequent procedures. A severe respiratory compliance event at the initial procedure was poorly predictive of its occurrence on subsequent procedures. No morbidity was associated with intraoperative severe respiratory compliance events.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.